Maintenance measures - 250 h
4812165001.pdf
2023-05-26
Maintenance measures - 250 h
Every 250/750/1250/1750..... hours of operation
(every 3 months)
Park the roller on a level surface.
The engine must be switched off and the
parking brake activated when checking or
adjusting the roller, unless otherwise specified.
Park the roller on a level surface.
The engine must be switched off and the
parking brake activated when checking or
adjusting the roller, unless otherwise specified.
Battery - Check condition
Fig. Battery
The batteries are sealed and maintenance-free.
Make sure there is no open flame in the vicinity
when checking the electrolyte level. Explosive gas
is formed when the alternator charges the battery.
Make sure there is no open flame in the vicinity
when checking the electrolyte level. Explosive gas
is formed when the alternator charges the battery.
When disconnecting the battery, always
disconnect the negative cable first. When
connecting the battery, always connect the
positive cable first.
When disconnecting the battery, always
disconnect the negative cable first. When
connecting the battery, always connect the
positive cable first.
The cable shoes should be clean and tightened.
Corroded cable shoes should be cleaned and
greased with acid-proof Vaseline.
Wipe the top of the battery.
115
Содержание DYNAPAC CA1300 D
Страница 2: ......
Страница 22: ...Introduction 4812165001 pdf 2023 05 26 4 ...
Страница 28: ...Safety Optional 4812165001 pdf 2023 05 26 10 ...
Страница 49: ...Machine description 4812165001 pdf 2023 05 26 4812129673 Warning CALIFORNIA Proposition 65 31 ...
Страница 57: ...Machine description 4812165001 pdf 2023 05 26 39 ...
Страница 66: ...Machine description 4812165001 pdf 2023 05 26 48 ...
Страница 96: ...Operating instructions Summary 4812165001 pdf 2023 05 26 78 ...
Страница 98: ...Operating instructions Summary 4812165001 pdf 2023 05 26 80 ...
Страница 104: ...Maintenance Lubricants and symbols 4812165001 pdf 2023 05 26 86 ...
Страница 117: ...Maintenance Maintenance schedule 4812165001 pdf 2023 05 26 Service Checklist 99 ...
Страница 118: ...Maintenance Maintenance schedule 4812165001 pdf 2023 05 26 100 ...
Страница 140: ...Maintenance measures 250 h 4812165001 pdf 2023 05 26 122 ...
Страница 194: ...Maintenance measures 1500 h 4812165001 pdf 2023 05 26 176 ...
Страница 238: ...Maintenance 3000 5000 7000 h 4812165001 pdf 2023 05 26 220 ...
Страница 284: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden www dynapac com ...