7 Parameter description
15-04-2016 40 7000.05052
NOTICE!
The flash memory is designed to accommodate 10,000 write cycles. If this command is
executed more than 10,000 times, the correct operation of the flash memory can no
longer be guaranteed.
Avoid performing frequent saves.
After 10,000 save cycles, replace the device.
Restore default parameters
Tab. 45: Restoring the parameters
Index
Subindex Name
Type Attr.
Default value Meaning
0x1011 00
Number of
entries
U8
ro
6
Number of object entries
01
Restore all
factory
parameters
U32
rw
1
Restore all factory settings
02
Restore factory
communication
U32
rw
1
Restore all factory settings for
communications parameters (0x0000 to
0x1FFF)
03
Restore factory
application
U32
rw
1
Restore all factory settings for
application parameters (from 0x2000)
04
Restore factory
application
parameters
U32
rw
1
Restore the user’s last saved settings
for application parameters (from
0x2000)
05
Restore
parameter set
U32
rw
1
Application parameters for direct
changes (set 1)
06
Restore
parameter set
U32
rw
1
Application parameters for direct
changes (set 2)
The object “Restore Default Parameters” loads the standard configuration parameters.
The standard configuration parameters are either those as delivered or those last saved.
Read access supplies information about the restore options. Writing the “Load” signature
to the respective sub-index initiates the restore procedure:
Tab. 46: “Load” signature
Signature
ISO 8859 (“ASCII”)
hex
MSB
d
64h
a
61h
o
6Fh
LSB
l
6Ch
The status as delivered may be loaded only when the output stage is switched off.
To activate the parameters restored by Restore Factory Settings, a Reset Node
command must be executed.