7 Parameter description
15-04-2016 39 7000.05052
Manufacturer’s hardware version
Index
Subindex Name
Type Attr.
Default value Meaning
0x1009 00
Manufacturer’s
hardware
version
Vis
strin
g
const –
Hardware version
The segmented SDO record must be read to determine the manufacturer’s hardware
version.
Manufacturer’s software version
Index
Subindex Name
Type Attr.
Default value Meaning
0x100A 00
Manufacturer’s
software
version
Vis
strin
g
const –
Software version
The segmented SDO record must be read to determine the manufacturer’s software
version.
Store parameters
Tab. 43: Saving parameters
Index
Subindex Name
Type Attr.
Default value Meaning
0x1010 00
Number of
entries
U8
ro
6
Number of object entries
01
Save all
parameters
U32
rw
1
Saves all parameters
02
Save
communication
parameters
U32
rw
1
Save the communication parameters
(object dictionary entries 0x0000 to
0x1FFF)
03
Save application
parameters
U32
rw
1
Save the application parameters
(object dictionary entries 0x2000 to
0x6FFF)
04
SAVE
application
parameters 1
U32
rw
1
Save application parameters for direct
changes (set 1)
05
SAVE
application
parameters 2
U32
rw
1
Save application parameters for direct
changes (set 2)
06
Save calibration
parameters
U32
ro
1
Save calibration parameters
The “Save Parameters” object saves the configuration parameters into the flash memory.
Read access supplies information about the save options. Writing the “Save” signature to
the respective sub-index initiates the save procedure.
Tab. 44: “Save” signature
Signature
ISO 8 859 (“ASCII”)
hex
MSB
e
65h
v
76h
a
61h
LSB
s
73h