Start-up Procedure
Application 4:
Brushless DC servomotor 3564 K 024 B without load controlled by
servo amplifier BLD 5606-SH4P; max. speed 8 000 rpm.
Starting values of servo amplifier components:
R7
= 33 k
Ω
R1
= 120 k
Ω
C1 =
1 µF
C2 =
33 nF
Speed command
Diagram 1
Measurement 1
(input signal)
Comment
- The speed command is applied to contact 14 of the connector.
Time
[sec]
A
b
so
lu
te
S
p
ee
d
c
o
m
m
an
d
[
V
]
Motor without load
Diagram 2
Measurement 2
(output signal)
Comment
- The output signal corresponds to the speed of the motor, it is measured
on contact 15 of the connector (Motor-Speed Monitor).
Motor
-Speed Monitor
[V]
Specifications subject to change without notice