15
1. No special care no no no 0,3 m
2. Twisted wires (see figure 1) slightly slightly slightly 1,0 m
3. Shielded Hall sensor wires (see figure 2) no yes yes 5,0 m
4. Shielded Hall sensor and phases wires yes yes yes 5,0 m
(see figure 3)
To:
perturbations To environment reduced
From: perturbations From environment reduced
Self:
self-perturbations reduced
Length: maximum cable length
In case of wires longer than the standard product (0,3 m), it is recommended to use
the following cable sections:
Phase, brushless DC servomotors type, 2036 ... B, 2444 ... B: 1,0 mm
2
/ AWG 18;
Phase, brushless DC servomotors type, 3056 ... B, 3564 ... B: 1,5 mm
2
/ AWG 16;
Hall sensors, brushless DC servomotors 2036, 2444, 3056 and 3564: 0,5 mm
2
/ AWG 20;
Note:
If wires longer than 5 m please consult us.