c. Functions: 

There  are  two  network  types  for  FBs-CMZBRs.  One  is  Peer-to-Peer  type  in 
which each device is in Master mode and can communicate each other  when 
both are in a valid RF communication range. 
The other is network type is Star type in which Slave devices only communicate 
with  the  only  one  Master.  And  the  Master  device  can  communicate  with 
multiple Slave devices. 
Users  can  configure  FBs-CMZBR  manually  by  QCU  utility  program  (described 
later in this document). 
FBs-CMZBR can be configured as a Master or a Slave. For two any two devices 
to be able to communicate, they must be set to a same PAN ID. If users want to 
operate two separate wireless networks in a same physical area, please group 
the  FBs-CMZBR  by  different  PAN  ID.  Each  device  will  only  receive  RF  packets 
with a same PAN ID.   

 

 

 

 

When a Master mode FBs-CMZBR sends RF packets, it broadcasts the packet to 
all the devices with the same PAN ID. On the other hand, when a FBs-CMZBR, as 
a Slave, sends data wirelessly, it only sends the data to the Master with a same 
PAN ID.  In order for  a Slave to work with  a Master, user must pair each other. 
After successful pairing, the Slave will remember the Master’s address and will 
be able to send RF packet directly to the Master.   

 

 

 

 

Содержание FBs-CMZBR

Страница 1: ...ial data from wired interface RS485 RS232 into RF packets and vice versa With robust RF protocol the FBs CMZBR can be used to form a wireless network with star or peer to peer structure 1 Introduction a Button connector i RS485 Type ii RS232 Type b Default value Com port setting 9600 7 E 1 PAN ID 0x1234 2 Byte Channel 26 Device Model Master Broadcast Transmit ...

Страница 2: ...ed as a Master or a Slave For two any two devices to be able to communicate they must be set to a same PAN ID If users want to operate two separate wireless networks in a same physical area please group the FBs CMZBR by different PAN ID Each device will only receive RF packets with a same PAN ID When a Master mode FBs CMZBR sends RF packets it broadcasts the packet to all the devices with the same...

Страница 3: ...it the data received from wired interface In contrast to the Working mode there is a Configuration mode which will be detailed further in later section a RS485 Type i Connect DC power wire to the green connector shown above Please notice the polarity The input voltage ranges from 7 to 24 volt When the power is applied to FBs CMZBR the green light in opposite side would go on or go flashing dependi...

Страница 4: ...k in a same Star network Firstly press the Config Binding button on a Master device and then green light blinks Secondly press the Config Binding button on a Slave device then green light on Slave blinks also When pairing is done successfully the green lights will stop blinking and turn on Since a pairing request would last for 30 seconds before it is cancelled users must press both devices within...

Страница 5: ...nter Configuration mode Press Enter Configuration 1B 1B button and the target device will enter into Configuration mode Actually this is done by sending 2 consecutive 0x1B codes into the connected device c Set Baud Rate That is the baud rate of cable communication By choosing the desired Baud rate the QCU will set the baud rate inside the connected device d Parity Enable ...

Страница 6: ...Set Device Function There are four different functions Master coordinator Slave End device One2One Master and One2One Slave By choosing the desired function the QCU will set the device function inside the connected device j Set Address No need to set self address it is defaulted k Set Personal Area Network ID PAN ID Enter four hexadecimal digits into the text box and press the Set PANID button l D...

Страница 7: ...the device will leave Configuration mode and enter Working mode The action will not save the setting adjust by the user If the user wants to keep the setting change please press Save Configuration button before leaving the Configuration mode 5 Initialization Turn off the power of FBs CMZBR Hold config binding button and power up Hold the button for 3 seconds then release the button The system is i...

Страница 8: ... causes the data transmission fails occasionally Put the communicating device in nearer distance Remove RF blocking barrier Green light on but Red light blinking 1 Wrong Baud rate Data Bit Parity setting Check Baud rate Data Bit and Parity setting The setting for FBs CMZBR must be consistent with the device eg PLC or computer connected via wire interface RS232 RS485 2 Loose connector prevent elect...

Отзывы: