FATEK Automation Corp.
www.fatek.com
7
Users can manually enter the AT command for FBs-CMZBR. There are two text
boxes which are used to enter AT command. One is for hexadecimal code and
the other is for entering human readable characters. Explanation of AT
commands is not in the scope of this document.
o.
Save Configuration result
The changed setting is firstly kept temporarily in the RAM of the connected
device. Users must save the setting into flash so as the setting get effective
when power-on. By press “Save Configurations” button, the setting will be
saved into the flash and kept forever.
p.
Reset Device
By press “Reset Device” button, the device will reset itself.
q.
Exit Configuration without Save
By press “Exit without Save” button, the device will leave Configuration
mode and enter Working mode. The action will not save the setting adjust by
the user. If the user wants to keep the setting change, please press “Save
Configuration” button before leaving the Configuration mode.
5.
Initialization
Turn off the power of FBs-CMZBR. Hold config/binding button and power up.
Hold the button for 3 seconds then release the button. The system is initialized.
(This function is built in f
irmware version 3.3 and versions afterwards .)
Follow Section4“Using QCU”to open port, then power up FBs-CMZBR. You will
see firmware version shown on data display area. This information appears only in
the FBs-CMZBR boot.
6. Trouble shooting
In case the FBs-CMZBR fails to transmit data smoothly, check LED light for the hint
of resolutions.
LED light
Possible Problems
Solution
No light
No power
Check power chord. Make sure
the power line is firmly connected.
Green light
1. Master is off
Master power on.