8 -9
●
TO Sxxx : S0
≦
Sxxx
≦
S999
(
Displayed in WinProladder
)
or
TO Sxxx : S0
≦
Sxxx
≦
S999
(
Displayed in FP-07
)
This instruction describes the step to be transferred to.
【
Example
】
WinProladder
FP-07
Y1
Y0
M1924
STP S0
STP S20
X0
X1
Y2
STP S21
Y3
STP S22
STP S23
X2
X3
X5
Y4
X4
M1924
STP S0
Y1
Y0
Y2
STPEND
X1
STP S20
X2
X4
X0
STP S21
Y3
STP S22
X3
Y4
X5
TO S20
TO S21
TO S22
TO S0
TO S23
TO S0
FROM S22
FROM S20
STP S23
ORG
TO
STP
AND
OUT
FROM
AND
TO
TO
STP
OUT
STP
OUT
FROM
AND
TO
STP
OUT
FROM
FROM
AND
TO
STP
AND
OUT
FROM
AND
TO
STPEND
M1924
S0
S0
X0
Y0
S0
X1
S20
S21
S20
Y1
S21
Y2
S21
X2
S22
S22
Y3
S20
S22
X3
S23
S23
X4
Y4
S23
X5
S0
【
Description
】
: 1. When ON, the initial step S0 is ON. If X0 is ON, then Y0 will be ON.
2. When S0 is ON: if X1 is ON, then steps S20 and S21 will be ON simultaneously and Y1 and Y2 will
also be ON.
3. When S21 is ON: if X2 is ON, then step S22 will be ON, Y3 will be ON and S21 and Y2 will be OFF.
4. When S20 and S22 are ON at the same time and the transferring condition X3 is ON, then step S23
will be ON (if X4 is ON, then Y4 will be ON) and S20 and S22 will automatically turn OFF and Y1 and
Y3 will also turn OFF.
5. When S23 is ON: if X5 is ON, then the process will transfer back to the initial step, i.e. So will be ON
and S23 and Y4 will be OFF.