www.fastech.co.kr
Control I/O Signal
28
5) Stop Input
Stop(Soft) input signal is to stop motion patterns under operation. The deceleration
condition until stop follows deceleration time value and start speed value which is set
existing. Stop signal is recognized as ON status level, pulse width must be over 10ms.
6) Jog+ and Jog- Input
When Jog+ or Jog- signal is [ON], the motor rotates clockwise or counterclockwise until it
reaches the hardware limit or the software limit. Jog motion pattern is subject to jog
related parameters (No.7: start speed, No.6: speed, No.8: Acc Dec time).
Motion
pattern
signal
input
Motion pattern
Plus direction
direction
Input
Input