DRAFT

beFore draInIng

• 

place a gray board (chip board)on the 

positioning deck, the rear edge against the back 

support. 

• 

put a stack of papers (approximately 4 cm/ 1.5” 

thick) on the position deck in portrait position 

(the short edge against the deck). close the 

clamp and turn the table to gluing position.

• 

the glue has to be melted before the glue 

cartridge can be drained. use the pur 

temperature setting for pur -glue and the eVa 

setting for eVa -glue.

11. draInInG THe Glue carTrIdGe 

11. draInInG tHE GLuE cartrIdGE

Figure 10-x X

draInIng tHe pur glue cartrIdge

• 

cover the book block spine with gray board 

so that the long edge of the board is towards 

you (the long edge is parallel with the glue 

applicator rail).

• 

Move the heating dock sideways close to the 

book block by using the applicator handle. 

Move the gray board against the back wall 

of the glue cartridge docking station. apply a 

sufficient amount of glue on the gray board by 

moving the unit back and forth from applicator 

handle.

• 

stop the heating dock in the middle of the paper 

block. remove the gray board by pulling it 

towards yourself, throw out the greyboard. Move 

the heating dock right over the edge of the 

paper block.

• 

repeat the steps until the glue roller stops 

applying glue on the gray board and it is empty, 

add a small amount of eVa glue and repeat 

twice.

• 

leave a small amount of eVa glue in the 

cartridge.

Содержание Pureva XT

Страница 1: ...Main parts and controls 4 3 How to use main steps 5 4 How to use step by step 6 Step 1 Mounting the book block 6 Step 2 Trimming 14 Step 3 Mounting the cover 15 5 Copyright trademarks and warranty 18...

Страница 2: ......

Страница 3: ...s simple and quick to clean the glue cartridge which can be reused or replaced Precise electronic temperature control Overview Specifications Europe U S A Machine cycles hour Up to 450 Up to 450 Capac...

Страница 4: ...for glue cartridge cap 7 EVA glue cartridge 8 PUR glue cartridge 9 soft cover nipping tool front 10 soft cover nipping tool back 11 hard cover nipping tool front 12 hard cover nipping tool back 13 th...

Страница 5: ...ble 3a Clamp handle 3b Support rod 3c Paper guide for soft and hard covers 3d Turn table front plate 3e Fastening holes for paper guide 4 Temperature control panel 4a Indicator lights 4b Temperature s...

Страница 6: ...fting from the wrong locations can result in personal injury and damage to the machine Use caution when lifting the machine The machine is delivered with a separate storage locker The storage locker i...

Страница 7: ...operated without positive ventilation Once cleaned of PUR glue the glue cartridge can be used multiple times If the glue head is not cleaned immediately after use the PUR glue solidifies and the cart...

Страница 8: ...hen the indicator light is blinking the glue head has not yet reached the selected temperature The machine is equipped with timer and auto off feature The timer starts when the machine is switched on...

Страница 9: ...aining isocyanate Glue fumes can be harmful Read the material safety data sheet for the PUR glue before using the glue Do not use PUR glue without sufficient fume extraction and proper ventilation Fol...

Страница 10: ...e heating or the machine is switched off even when the glue cartridge is removed from the machine DO NOT TOUCH ANY HOT SURFACE AT ANY TIME OR YOU RISK INJURY While the machine is turned on assume all...

Страница 11: ...ridge is securely connected in the heating dock positioned under the bypass vent which must be in the open position 7 3 INSTALLING the GLUE CARTRIDGE TO THE HEATING DOCK Always Turn the table down bef...

Страница 12: ...r on glue cartridge by pressing blue locking lid and push the gripper to its place using the guiding screws marked in green highlight in the image Release the blue locking lid trigger once the cartrid...

Страница 13: ...ISK INJURY o o WARNING Hot PUR glue emits fumes which can be harmful if inhaled Before removing the cap ensure that the externally connected fume extractor is on and operating and the glue cartridge i...

Страница 14: ...ridge heating dock The thermal casing must be removed to open the glue tank cap or when installing or removing the glue cartridge HEAT SHIELD The machine is delivered with a separate front heat shield...

Страница 15: ...Fastbind PUREVA XT user manual v 1 0 Maping Co 2014 15 DRAFT 10 FUNCTIONS...

Страница 16: ...h letter S and hard cover tools with letter H Install the back support to the rear part of the positioning deck against the back limiter The back support is held tight with magnets The moving tool is...

Страница 17: ...shaped book spine o o CAUTION Do not use roughening after glue has been applied to the book spine as glue destroys the roughening parts APPLYING GLUE Glue is applied by moving heated hot glue cartrid...

Страница 18: ...er the book block spine with gray board so that the long edge of the board is towards you the long edge is parallel with the glue applicator rail Move the heating dock sideways close to the book block...

Страница 19: ...62 6022 Fax 358 9 562 6215 Helsinki 2006 01 05 _______________________ Lauri Huotari Managing Director Espoo 25 6 2014 DECLARATION OF CONFORMITY We Maping Company hereby declare that following product...

Страница 20: ...vice outlet or by the manufacturer at Helsinki Finland All transportation charges on parts submitted for repair or replacement under this warranty shall be paid for by the purchaser All service under...

Отзывы: