Fastbind PUREVa Xt UsER manUal | v 1.0 | © maping Co 2014
11
DRAFT
7.4 handling the glue tank cap
•
the machine is delivered with two glue cartridge caps and a
cap hook for handling them. the cartridge cap is placed on the
glue cartridge to close the tank and keep the glue fumes inside
the tank. use one cap for the glue cartridge with pur glue and
another for eVa glue.
•
keep the cap on the glue cartridge while storing it in the gripper to
prevent the cap from getting lost and keeping any hot glue fumes
inside the glue cartridge.
•
open the cap only for adding glue or checking the glue level.
otherwise, keep the cap on to prevent glue fumes from escaping.
o warnIng!
▪
the tank cap is hot! do not toucH any Hot
surFace at any tIMe or you rIsk InJury
▪
always use the cap hook to handle the cap.
o warnIng!
▪
Hot pur glue emits fumes which can be harmful if
inhaled. before removing the cap, ensure that
- the externally connected fume extractor is on and
operating
- and the glue cartridge is securely connected in the
heating dock, positioned under the bypass vent, which
must be in the open position.
7.3 installing the glue cartridge
tO the heating dOck
•
always turn the table down before installing or removing the glue
cartridge
•
Install the glue cartridge to the heating dock jaw by sliding it in
aprox 3/4 of the way in.
•
the correct position to attach it is shown in the image with green
highlight.
•
before pushing the glue cartridge all the way in, check that the slot
on the torque wheel fits to the corresponding wedge of the heating
dock.
•
the torque wheel can be rotated to the correct position by moving
the heating dock left or right using the applicator handle.
•
push the glue cartridge all the way in to the locked position.
7. GLuE cartrIdGE HandLInG
•
to remove the gripper press the blue trigger with your thumb.
•
pull towards you about 2 cm in order to release the lock.
•
remove the gripper from the machine and store it into the gripper
locker
•
check that safety latch is down, (marked with green highlight)
•
check that the machine is set for the correct glue type temperature
(pur or eVa)
•
place the thermal protection (covers) back in the correct place.