9
7.3
ELECTRIC HOOK UP
Before making any electric hook up, carefully check that the mains voltage corresponds to the data given
on the voltage tag (positioned near the tyre-changer plug).
Following requirements are essential:
-
the system must be equipped with a good earthing circuit
-
the machine must be connected to a power supply line circuit breaker set at 30 mA
-
the plug must be properly protected against overcurrent by means of either fuses or an automatic
magneto-thermal switch with rated values as shown in the chart.
Read the required power draw as highlighted in the data plate fixed to the tyre-changer and make sure that the
electric network is properly dimensioned to it.
WARNING! Make sure that the feeding cable, once connected to the electric network, can freely move and
follow the stroke the chuck holder without risk of damage.
Failure to comply with above mentioned requirements will relief the manufacturer from any and all liability
for any injury to persons or damage to things referred to these acts and it will involve the immediate expiry
of warranty.
Check the tyre-changer to the network, turn on the main switch (5, fig. A) and check the rotation direction of the
motor. It must correspond to the direction shown by the arrow (6, fig. A). If not, have two wires in the plug (3ph)
reversed by professional staff.
CHECK OF MOTOR ROTATION
10 A
10 A
8 A
8 A
13,5 A
13,5 A
6,3 A
6,3 A
Interruttore
Interruttore
Switch
Switch
Interrupt.
Interrupt.
Schalter
Schalter
Interruptor
Interruptor
220 V. - 3 Ph. - 50/60 Hz.
240 V. - 3 Ph. - 50/60 Hz.
380 V. - 3 Ph. - 50/60 Hz.
415 V. - 3 Ph. - 50/60 Hz.
Alimentazione
Power supply
Alimentation
Stromversorgung
Alimentación
A
5
6
Any work on the electrics, however
minor, must be done exclusively be
professional staff.
Содержание RGU588E