Use and Maintenance Manual
– Spare Parts
Page 19
PROBLEMS – CAUSES - SOLUTIONS
PROBLEMS
CAUSES
SOLUTIONS
Not working
Main switch on "0
”
position
Put switch on
“I” position
Transformer
fuses
or
general protection fuses
blown
Replace the blown fuses
Electrical system
fault
Check the efficiency of the
connections.
Control micro
Check the micro is placed
at the centre of the cam as
described in Fig. 4
– Cable
assembly
Descent is extremely
slow
The choke is not working
properly
Clean the choke
Tubes blocked
Clean the tubes
The motor is rotating
properly but the lift is
not working or very
slow
Oil solenoid valve blocked
in the open position
Clean solenoid valve
Filter clogged
Clean filter
Piston gasket worn or
damaged
Replace gasket
Pump worn or damaged
Check the efficiency of the
pump
and
replace,
if
necessary