ELECTRICAL CONNECTION
The standard machine is prepared to work with three phase 380V/50HZ mains
voltage. A specific request must be made if the mains voltage on the system is
three phase 220V/50Hz.
Before connecting to the mains, check the voltage on the machine plate.
You are advised not to connect the machine to the electrical mains until it is
completely positioned and assembled.
The user electrical system must comply with the standards C.E.I. 64.8
(CENELEC HD 384, IEC 364-4-41).
The following must be planned: an equipotent earthing system installed
upstream of the machine with an adequately sized differential circuit breaker
automatic system and must be coordinated with the earthing system as
specified in standard CEI 64-8.
Connection to the mains must be made with a power supply cable with 2 poles
+ earthing with a minimum 2.5 mm section following these instructions:
Fig. 5
–
Electrical connection
1.
Open the box.
2.
Pass the power supply cable
through the cable gland.
3.
Connect the cable phases to the
terminals T,S,R, (Fig.5) and the
earthing
cable
to
the
PE
equipotent terminal.
4.
Check the voltage for which the
lift is prepared is equal to the line
voltage.
5.
Power the electrical equipment.
The
“
ELECTRICAL
DIAGRAM
”
table outlines the diagram of the
electrical system inside the machine. Run an electrical continuity test having
correctly connected the electricity.
Содержание FZ63/3S
Страница 2: ......
Страница 32: ...Page 32 Use and Maintenance Manual Spare Parts THREE PHASE ELECTRIC DIAGRAM...
Страница 33: ...Use and Maintenance Manual Spare Parts Page 33...
Страница 35: ...Use and Maintenance Manual Spare Parts Page 35 SINGLE PHASE ELECTRIC DIAGRAM...
Страница 36: ...Page 36 Use and Maintenance Manual Spare Parts...