
Fasep 2000 srl
Rev. 1.1
Balatron B350.G3
10 September 2012
4-3
F
IG
.
17
F
IG
.
18
4.3
How to control the calibration of Wheel Balancer B350-T
Press <+/-> to select
CAL TEST
.
Place the truck flange (see picture 17).
Put the calibration weight as shown in the
picture 18.
Press
<FINE>
to see actual values. 160-0
(±3)
is correct result.
When all LED (left side) are lit, calibration
weight
must be at exactly 6 o’clock.
If no, press
<FUNC>
to calibrate position.
Turn the flange until the calibration weight is
located at 6 o’clock.
Press
<SET>
to calibrate the position.
Press
<MODE/ESC>
to return to normal
balancing mode.
F
IG
.
19