![FARMSCAN 7000 Series Скачать руководство пользователя страница 62](http://html.mh-extra.com/html/farmscan/7000-series/7000-series_operators-manual_545376062.webp)
March 2020
www.farmscan.com.au
AM-7500-5
61
Alarms (3)
ALARM OPTIONS
An Alarm can be set up with many different options which are listed and explained here.
1.
Alarm
: Select the
Alarm
button to go to the
Value and Unit Selection
page.
a.
Select what value (speed, rate, tank level etc.) you wish to alarm.
b.
Once selected, choose a unit.
c.
Select the green
Tick
button to accept these changes.
2.
Alarm Level
: Select to toggle between
Normal
and
Critical.
a.
Normal:
The Alarm will run as a notification alarm. The system will continue operating but
the user will be informed that the typical operating conditions have been breached.
b.
Critical:
When a critical Alarm is triggered, the system will be forced out of Run Mode into
Hold Mode. These should be considered for safety and also as risk reduction/
3.
Alarm On
: Select to toggle between
Always
and
Run only
.
a.
Always
: The Alarm is always active.
b.
Run only
: The Alarm will only activate when the implement is running.