Tank Setup
SETUP CONTROL VALVE (PWMVOLT)
Selecting the
PWMVolt
option will allow for auto calibration & manual calibration of an airseeder setup
using a proportianal/hydrualic valve to drive the metering shaft.
Type
: PWMVolt
Auto Calibrate:
Automatically finds the Min/Max settings for the valve through a series of tests.
Refer to PAGE 42 for more information
Maximum
: The maximum voltage to apply to the valve.
(Set 10v as Max to start)
Minimum
: The minimum voltage to apply to the valve. This is typically the lowest voltage that the valve
will still operate under.
(Set 2v as Min to start)