![FARMSCAN 7000 Series Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/farmscan/7000-series/7000-series_operators-manual_545376019.webp)
March 2020
www.farmscan.com.au
AM-7500-5
18
Machine Setup
Prime Mode operation explanation
The
Prime Mode
operation turns on the Seeder metering system before speed is detected from the speed
sensors. This allows product to begin metering before moving off preventing any missed areas due to a
metering lag. The product will be regulated as if the implement was travelling at the
Prime Speed
. If the
implement exceeds the
Prime Speed
or the
Prime Time
then the product will be regulated normally.
1.
Enable Prime
a.
If
Prime Mode
is enabled, the metering control will enter Prime Mode instead of Run Mode.
2.
Prime Time Mode
a.
Set Time
: When
Prime
is enabled and
Prime Time
set, after X seconds the metering control
will revert to Run Mode.
b.
Continuous
: The unit will remain in Prime Mode indefinitely.
NOTE:
This should
NOT
be
used in standard operation but it is useful for “stand still” testing and demonstration.
3.
Prime Time
a.
If
Prime Mode
is entered, after the selected number of seconds metering control will revert
to Run Mode.
4.
Prime Speed
a.
When in
Prime Mode
, the metering control is regulated as if the implement was travelling
at the
Prime Speed
.
b.
If the implement exceeds the
Prime Speed
, metering control will revert to Run Mode.
Speed
Control
Rate
Prime
Speed
Revert
to Run
Mode
Rate @
Prime
Speed