27
DRYING TABLES — C-2160B
The above drying capacities are estimates based on drying principles, field results, and computer simulations. Variances may occur
due to the grain’s physiological factors (kernel size, chemical composition, variety, maturity), escessive fines, weather conditions, etc.
CORN ...dry & cool
190 °F
210 °F
230 °F
% Unload
Dry
Capacity
% Unload
Dry
Capacity
% Unload
Dry
Capacity
in
out
Rate
Tim e
Dry Bph
Rate
Tim e
Dry Bph
Rate
Tim e
Dry Bph
17
15
69
20
1595
79
17
1823
18
15
52
26
1202
59
23
1374
19
15
42
32
980
48
28
1120
54
25
1260
20
15
36
38
833
41
33
952
46
29
1071
21
15
31
43
724
36
38
827
40
34
931
22
15
28
49
638
31
43
729
35
38
820
23
15
24
55
566
28
48
647
31
43
728
24
15
22
62
505
25
54
577
28
48
649
25
15
20
69
452
22
61
516
25
54
581
26
15
17
77
405
20
68
463
22
60
521
27
15
16
86
364
18
75
416
20
67
468
28
15
14
95
328
16
83
374
18
74
421
29
15
13
106
296
15
92
338
16
82
381
30
15
12
116
268
13
102
307
15
91
345
31
15
11
128
244
12
112
279
14
99
314
32
15
10
140
223
11
122
255
12
109
287
33
15
9
152
205
10
133
235
11
118
264
34
15
8
165
190
9
144
217
11
128
244
35
15
8
177
177
9
155
202
10
138
227
CORN ...full heat
190 °F
210 °F
230 °F
% Unload
Dry
Capacity
% Unload
Dry
Capacity
% Unload
Dry
Capacity
in
*out
Rate
Tim e
Dry Bph
Rate
Tim e
Dry Bph
Rate
Tim e
Dry Bph
18
17
83
25
1910
94
21
2183
19
17
67
30
1554
77
26
1776
86
23
1998
20
17
57
35
1323
65
31
1512
73
28
1701
21
17
50
41
1154
57
36
1319
64
32
1484
22
17
44
46
1020
50
40
1166
57
36
1311
23
17
39
52
907
45
45
1037
50
40
1166
24
17
35
58
809
40
51
925
45
45
1040
25
17
31
65
723
36
57
826
40
50
930
26
17
28
72
647
32
63
739
36
56
832
27
17
25
81
580
29
71
663
32
63
746
28
17
23
90
521
26
79
595
29
70
670
29
17
20
100
470
23
87
537
26
78
604
30
17
18
110
425
21
96
486
24
86
546
31
17
17
121
387
19
106
442
21
94
497
32
17
15
132
354
17
116
404
20
103
455
33
17
14
144
326
16
126
372
18
112
419
34
17
13
155
302
15
136
345
17
121
388
35
17
12
166
282
14
145
323
16
129
363
*represents the target moisture out of the dryer. Expected final moisture in the bin is 15.0%
Based on 100% Unload rate of
2315 bph
MOISTURE
MOISTURE
Содержание C-21100B
Страница 22: ...20 ...
Страница 36: ...34 Fig 6 3 LP vaporizer assembly Fig 6 4 ASC control panel ...
Страница 49: ...Fig 8 1 Power circuit 220V 3 PH for C 2130B C 2140B C 2160B only 47 4B0280A TIF ...
Страница 50: ...48 Fig 8 2 Power cirucit 220V Part wind start for C 2175B C 21100 models only 4B0280C TIF ...
Страница 51: ...49 Fig 8 3 Power circuit 440V 3 PH for all C 2100B models 4B0280B TIF ...
Страница 52: ...Fig 8 4 Control circuit all models except part wind start p 1 of 3 50 4B0280D TIF ...
Страница 53: ...Fig 8 4 Control circuit all models except part wind start p 2 of 3 51 4B0280E TIF ...
Страница 55: ...Fig 8 5 Control circuit part wind start models only p 1 of 3 53 4B0280H TIF ...
Страница 56: ...Fig 8 5 Control circuit part wind start models only p 2 of 3 54 4B0280I TIF ...
Страница 58: ...Fig 8 6 Safety circuit portion of control circuit all models 56 4B0280G TIF ...
Страница 65: ......