16
pressure, close the fresh air louvers slightly until they
stay in the closed position, indicating a slight vacuum in
the lower reclaiming duct. See Fig. 3-4.
The louvers can be adjusted by moving the HFWL 1/2-
13 nuts located on the lover adjusting stud protruding
through the dryer floor panel on each side of the fan-
heater module. Fine adjustments can be made by
rotating the louver handle assembly. By moving the
louver assembly toward the center of the dryer, the
HFWL nut will pass through the keyhole slot in the floor
panel, allowing the louvers to be quickly moved to a
closed position when not in use. When adjusting lou-
vers, it is best to open each side approximately the
same
REAR OUTER FLOOR PANEL
The rear outer floor panel should be removed from C-
2100B1 series dryers only when the HR-2100B1 series
reclaimer is used to allow air to flow from the lower
reclaimer to the fan inlet enclosure.
HINGED RECLAIMER SIDE PANELS (HR-2100B1 HEAT
RECLAIMER OPTION)
The hinged reclaimer side panels allow easy access to
the lower part of the dryer for cleaning. They can also
be opened to allow exhaust air to escape when
reclaiming is not desired. When operating under these
conditions, fully open the fresh air louvers.
C-2100B1 SERIES PRESSURE COOL DRYER
(WITH FH/PC-2100 OPTION)
FRESH AIR LOUVERS
The fresh air louvers on the C-2100B series pressure
cool dryers should always be adjusted to the full open
position. See Fig. 3-4.
RECLAIMERS
Exhaust air cannot be reclaimed when pressure cool-
ing.
Fig. 3-4 Airflow diagram
Содержание C-21100B
Страница 22: ...20 ...
Страница 36: ...34 Fig 6 3 LP vaporizer assembly Fig 6 4 ASC control panel ...
Страница 49: ...Fig 8 1 Power circuit 220V 3 PH for C 2130B C 2140B C 2160B only 47 4B0280A TIF ...
Страница 50: ...48 Fig 8 2 Power cirucit 220V Part wind start for C 2175B C 21100 models only 4B0280C TIF ...
Страница 51: ...49 Fig 8 3 Power circuit 440V 3 PH for all C 2100B models 4B0280B TIF ...
Страница 52: ...Fig 8 4 Control circuit all models except part wind start p 1 of 3 50 4B0280D TIF ...
Страница 53: ...Fig 8 4 Control circuit all models except part wind start p 2 of 3 51 4B0280E TIF ...
Страница 55: ...Fig 8 5 Control circuit part wind start models only p 1 of 3 53 4B0280H TIF ...
Страница 56: ...Fig 8 5 Control circuit part wind start models only p 2 of 3 54 4B0280I TIF ...
Страница 58: ...Fig 8 6 Safety circuit portion of control circuit all models 56 4B0280G TIF ...
Страница 65: ......