8
USE A FLEXIBLE CONNECTION
HOSE DESIGNED FOR LP GAS.
SEE TABLE 2-1 FOR
RECOMMENDED LINE SIZE.
FUEL SUPPLY SYSTEM SHOULD
CONFORM WITH NATIONAL FIRE
PROTECTION ASSOCIATION STANDARDS.
CONSULT PROPANE SUPPLIER FOR
PROPER FITTINGS, CONNECTION
HOSE, AND SAFETY CONTROLS
REQUIRED TO MEET STANDARDS.
DO NOT USE A PRESSURE
REGULATOR AT THE SUPPLY TANK.
OPEN LP SHUT-OFF VALVES SLOWLY
TO PREVENT ACCIDENTAL CLOSING
OF EXCESS FLOW VALVES.
PROPANE SUPPLY
TANK. RECOMMENDED
MINIMUM OF 1,000 GALLONS
CONNECTED FOR LIQUID
DRAW.
LP CONNECTION
21SENS.DS4
PSC
ASC
C-2100B
C-2100B
SEE TABLE 2-1 FOR
RECOMMENDED LINE SIZE.
NATURAL GAS METER AND REGULATOR.
SEE TABLE 2-1 FOR REQUIRED PRESSURE
AND TYPICAL MAXIMUM FUEL FLOW RATES.
PSC
ASC
C-2100B
C-2100B
21SENS.DS4
NATURAL GAS CONNECTION
Fig. 2-1 Fuel hookup
Содержание C-21100B
Страница 22: ...20 ...
Страница 36: ...34 Fig 6 3 LP vaporizer assembly Fig 6 4 ASC control panel ...
Страница 49: ...Fig 8 1 Power circuit 220V 3 PH for C 2130B C 2140B C 2160B only 47 4B0280A TIF ...
Страница 50: ...48 Fig 8 2 Power cirucit 220V Part wind start for C 2175B C 21100 models only 4B0280C TIF ...
Страница 51: ...49 Fig 8 3 Power circuit 440V 3 PH for all C 2100B models 4B0280B TIF ...
Страница 52: ...Fig 8 4 Control circuit all models except part wind start p 1 of 3 50 4B0280D TIF ...
Страница 53: ...Fig 8 4 Control circuit all models except part wind start p 2 of 3 51 4B0280E TIF ...
Страница 55: ...Fig 8 5 Control circuit part wind start models only p 1 of 3 53 4B0280H TIF ...
Страница 56: ...Fig 8 5 Control circuit part wind start models only p 2 of 3 54 4B0280I TIF ...
Страница 58: ...Fig 8 6 Safety circuit portion of control circuit all models 56 4B0280G TIF ...
Страница 65: ......