160
(MT11 - Gb2012)
4+1
INTERCOMS
*
7+1
VIDEOINTERCOMS
Si 26MO/2
E
X
-
K
M
-
S
T
-
P
T
ONE WAY INTERCOM SYSTEM WITH SECONDARY DOOR STATIONS AND 1 MAIN COMMON STATION (multiple
entrance)
Main DOOR STATION
PROFILO series
MATRIX series
MODY series
...
PL71÷PL73
...
MA71÷MA73
...
MD71÷MD74
1
PL81÷PL89
1
MAS61÷MAS63 (
1
)
1
MD81÷MD812
1
PL91÷PL99 *
1
MA91÷MA93 *
1
MD91÷MD912 *
1
PL10P÷PL12P
1
MAS10P÷MAS12P
1
MD10÷MD124
...
PL21÷PL228
...
MAS22-MAS24
...
MD21÷MD228
...
PL20, PL50
...
MAS20
...
MD20, MD50
1
MD30
Secondary DOOR STATIONS
PROFILO series
MATRIX series
MODY series
X
PL71
X
MA71
X
MD71
X
PL81
X
MAS61 (
1
)
X
MD81
X
PL91 *
X
MA91 *
X
MD91 *
X
PL11P
X
MA11P
X
MD11
X
MD30
INTERNAL STATIONS
...
EX310
Exhito series intercom with 2 call buttons
...
EX320
Exhito series modular intercom
...
KM810W
Compact series intercom with 1 call button
...
ST720W
Studio series modular intercom
...
PT510EW
Project series intercom with 1 call button
VARIOUS ARTICLES
X
1473
Exchanger
1+X PRS240
Power supply with electronic ringing generator
1+X PA **
Door release push-button (optional)
1+X SE **
Electric door lock (12VAC-1A)
... Refers to number of users.
X Refers to the number of stairways.
(
1
) Or MA61÷MA63.
*
Rain shelters are used instead of back boxes and hood covers.
** Articles not supplied by ACI Farfisa.
Working instructions.
As the basic system described on page 183, with the following variations:
- The audio functions and door lock opening are automatically switched to the door station
which has made the call and remain in this state until a call from another entrance is
received.
- Services to secondary door stations are independent and can be operated at the same
time.
Notes
- For the connection of name-plate lamps, read notes 6, 7 and 8 of the installation
instructions on page 146.
- For wires dimensioning refer to the installation recommendations and table on page
146.
PA
SE
230V
127V
0
3
4
5
7
8
9
PRS240
1473
MD100
RP100
UP11
UP100
2
1
8b
9b
7b
6
9a 8a 7a
C
P
X
C+
2
1
Application diagram
When using MD100, RP100, UP11 and UP100
amplified external door stations as one-way second-
ary door stations, place this diagram on the diagram
on page 161 and line it up with the riser.
Warning.
- Cut jumper W1 in the RP100 external door stations.
- In UP series external door stations do not connect
and insulate the yellow wire.
- For alternate current wires refer to note 6 of the
installation instructions on page 146.