116
(MT11 - Gb2012)
Insertion of spacers between back boxes.
Spacers and cable bushing (not supplied
with the products) must be inserted before
brick work.
INSTALLATION
PROXIMITY READER FOR ACCESS
CONTROL
FP52PL
.
This article allows for the activation of 2 relays
by means of keytags or electronic ISO cards
based on transponder technology.
Programmable activation time from 1 to 63
seconds for every relay. 4 user cards and 1
master card supplied with the product. Acoustic
and visual control signals and 3-digit display to
view numbers and codes during set-up and
operation.
Technical data
Power supply 12Vac/dc ±10%
Stand-by current
0.1A
Maximum current consumption 0.25A
Contact ratings
24Vac - 2A
Max. number of cards
490
Max. number of Master cards 10
Number of relays
2
Relay time
1 to 63 sec.
Minimum recognition distance 3 cm
Maximum recognition time
1 sec.
Operating temperature
0° ÷ +40°C
Maximum permitted humidity
85% RH
Terminals
+/A positive or alternate current input
-/A
ground or alternate current input
PB
door open button
NC2 normally closed contact of relay 2
NA2 normally open contact of relay 2
C2
common terminal of relay 2
NC1 normally closed contact of relay 1
NA1 normally open contact of relay 1
C1
common terminal of relay 1
Card recognition LED. It turns ON dur-
ing card recognition.
Relay activation LED. It indicates relay
deactivation (red) or activation (green).
Program LED. It turns ON during system
programming.
Card cancellation and system setup
LED. It turns ON during Master or user
card cancellation and system setup.
ACCESS CONTROL KEYPAD
FC 52PL
.
Access control keypad with 12 digits and 2
relays for lock release. 4 programmable ac-
cess codes for each relay. Programmable door
opening time from 1 up 99 sec. for each relay
(or bistable operation of relay 1). Acoustic and
visual confirmation for entered keys, accepted
programming and for wrong codes.
Technical data
Power supply: 12Vac/dc ±10%
Stand-by current:
0.06A
Maximum current consumption: 0.15A
Contact ratings:
12Vac-2A
Numbers of codes for relays 1: 12 or direct
activation
Numbers of codes for relays 2: 12 or direct
activation
Activation time for each relay: from 1 to 99 sec.
(or bistable relay 1)
Operating temperature:
0° ÷ +40°C
Maximum permissible humidity: 85% RH
Terminals
NC2
normally closed contact of relay 2
NA2
normally open contact of relay 2
C2
common contact of relay 2
NC1
normally closed contact of relay 1
NA1
normally open contact of relay 1
C1
common contact of relay 1
ground or alternate voltage input
positive or alternate voltage input
P2
activation of the relay 2; if momentarily
connected to ground it allows the acti-
vation for the programmed time
P1
activation of the relay 1; if momentarily
connected to ground it allows the acti-
vation for the programmed time
EXTERNAL DOOR STATIONS
CD4134PL
CD4138PL
PL42PCDG
TD4100PL
Place the push-button panel back box at a
height of about 1.65m (5' 5") from the floor
keeping the front edges flush-mounted and ver-
tical to the finished plaster.
Position the camera in such a way that
sunlight or other direct or reflected light
sources with high intensity do not hit the
camera lens.
PL40PCDG
4+1
INTERCOMS
*
7+1
VIDEOINTERCOMS
P
R
O
F
I
L
O
Assembling modules side by side
Содержание ECHOS
Страница 1: ...ECHOS EXHITO COMPACT TECHNICAL MANUAL 2012 ELECTRONIC CALL SYSTEM...
Страница 94: ...92 MT11 Gb2012...