78
(MT11 - Gb2012)
1+1
INTERCOMS *
4+1
VIDEOINTERCOMS
Si 46MR/2
MULTI-WAY VIDEOINTERCOM SYSTEM WITH SECONDARY DOOR STATIONS ONLY AUDIO AND 1 MAIN
COMMON VIDEO STATION (multiple entrance)
EXTERNAL DOOR STATIONS
AGORA' series
PROFILO series
MATRIX series
MODY series
1
AG100V
...
PL71÷PL73
...
MA71÷MA73
...
MD72÷MD74
X
AG100A
1+X
PL81÷PL89
...
MAS61÷MAS63 (
1
)
1+X
MD82÷MD812
...
AG100T
1+X
PL91÷PL99 *
1+X
MA91÷MA93 *
1+X
MD92÷MD912 *
...
AG20
1
PL40PCED÷PL42PCED
1
MAS43CED
1+X
MD10ED÷MD12ED
...
AG21
PL40PED÷PL42PED
MAS43ED
1
MD41D
...
AG222
X
PL10PED÷PL12PED
X
MAS10PED÷MAS12PED
...
MD21÷MD228
X
AG30ED
...
PL21÷PL228
...
MAS22, MAS24
...
MD20, MD50
1
AG40CED
...
PL20, PL50
...
MAS20
...
241D
...
241DMA
...
241DMA
INTERNAL STATIONS
ECHOS series
EXHITO series
COMPACT series
...
EH9161CT
...
EX3100C
...
KM8111CW
...
EH9161CW
...
EX3160C
...
KM8111W
...
9083
...
EX3160
...
WB8111
...
WA9100T-W
...
WB3161
...
TA9160
...
TA3160
VARIOUS ARTICLES
X
1473
Exchanger
1+X
1181E
Timed power-supply
1+...
DV2D-DV4D
Video distributors
1+X
PA **
Door release push-button (optional)
1+X
SE **
Electric door lock (12VAC-1A)
... Refers to number of users.
(
1
) Or MA61÷MA63.
*
Rain shelters are used instead of back boxes and hood covers.
** Articles not supplied by ACI Farfisa.
Notes
- For audio compatibility we do not suggest to connect door stations
MODY series with internal devices ECHOS series.
- For the connection of name-plate lamps, read notes 6, 7 and 8 of the
installation instructions on page 50.
- For wires dimensioning and video connection refer to the installation
instructions and table on pages 50 and 51.
- If it is requested to monitor the main entrance it is necessary to
connect the terminal “4” of the videointercoms to the terminal “5” of
the exchanger art. 1473 connected to its own riser.
Working instructions.
As the basic system described on page 52, with the following variations:
- The audio-video functions and door lock opening are automatically
switched to the door station which has made the call and remain in this
state until a call from another entrance is received.
- Services to secondary door stations are independent and can be
operated at the same time.
Agorà door stations
Attention. In the door station AG100A of the
secondary entrances create the terminal
"E" cutting the red wire which connects the
door speaker AG30ED to the backlighting
board (see figure), than connect it to the
terminals "E" of additional AG100T’s (if
any).
In the door station AG100V of the main
entrance only cut and insulate the conductor
“E” (red wire).
The main entrance push-button panel must have separate common
terminals. One common terminal for each secondary door station. The
common terminals of push-buttons Profilo and Matrix series can be
separated only module by module.
The common terminals of push-button
Agorà series can be separated according
to the requirements, by cutting
opportunely the common rail or just do
not using it.
Common buttons
building “a”
Common buttons
building “b”
Common of
button 1 and 2
To separate
common of
buttons cut here
Common of
button 3 and 4
In Mody series the common terminals
of push-buttons can be separated
module by module or every 2 push-
buttons by cutting opportunely the
common rail which connects the
common terminals of push-buttons.