3.
Fix the induction cooking to countertop by screwing the four connectors located
under the induction cooking. The position of the ties can be adjusted according
to the thickness of the countertop. Scheme (3).
Electric connections
C
heck if your meter and fuses can handle the intensity absorbed by the induction
cooking and the other electrical equipment already plugged.
F
use rating (one per phase): 32 amps.
The device must not be connected with an extension or a multiple socket (danger
of fire).
U
se a connection with a terminal grounded, which must necessarily be connected
in accordance with standard NF C 15-100.
T
he electrical power supply line from the meter must not be less than 4
mm ² per conductor.
M
ake sure that, once the device is installed, the
power supply cable is easily accessible.
I
f the power supply cable is damaged it must be replaced by the manufacturer, its
after-sales service or similarly qualified persons in order to avoid a danger.
T
he qualified person must ensure that the electrical connection is correct and conform to
local standards.
-
T
he cable must not be bent or compressed.
-
T
he cable must be checked regularly and should be replaced by a qualified technician.
-
T
he device must be installed according to national electrical standards.