Страница 1: ...CH140GSM WEEKLY PROGRAMMABLE THERMOSTAT WITH INTEGRATED GSM ...

Страница 2: ...RAMS PROGRAMMABLE TEMPERATURES SETTING THE OPERATING PROGRAMS FUNCTIONS IN DETAIL PROGRAMS AVAILABLE PROGRAMMABLE TEMPERATURES KEYS AND ADVANCED FUNCTIONS RESET REMOTE PROGRAMMING VIA SMS SMS COMMANDS COMMANDS FOR ALARMS AND ALERTS COMMANDS FOR THE AUXILIARY RELAY RELAY 2 NO 230V POWER OR POWER SUPPLY RETURN ALERT MESSAGES 3 4 6 7 7 8 8 9 10 13 13 15 16 23 24 25 29 31 31 1 PROGRAMMABLE THERMOSTAT ...

Страница 3: ...igure 1 3 Remove the insulation protection on the baseboard by unscrewing the specific captive screw 4 Make the electrical connections as shown on page 5 5 Secure the baseboard to the wall or to the recessed box using the screws supplied 6 Reposition the insulation protection by tightening the screw 7 Open the SIM holder compartment at the back of the programmable thermostat as shown in Figure 2 8...

Страница 4: ... to contacts that are dry and voltage free and with cables no longer than 3 m GSM FUNCTIONALITY VERIFICATIONS The programmable thermostat connection to the GSM network can be detected by the antenna symbol and three bars The antenna symbol flashes if the module is not registered to the GSM network e g no coverage SIM not inserted or blocked by PIN etc Once the registration is complete the antenna ...

Страница 5: ...rectly and close the latch of the SIM holder ERR 311 SIM has PIN protection remove the SIM and insert it into a phone to remove the PIN protection function N B Any other error codes that may appear must be noted to then contact the technical support SYMBOL Signal level None flashing 0 1 2 9 10 14 15 19 20 30 99 Low Acceptable Good Excellent n r VALUES RS BE VALUE 0 0 2 5 3 2 6 4 1 0 2 0 4 6 6 4 12...

Страница 6: ...blackout periods since all the settings are saved in a non volatile memory Even if the power supply is not available for long periods the clock calendar operation is guaranteed by an internal battery 5 B 6 A 7 1 Caldaia CH140GSM 2 Gd 4 L N In2 In1 Gd Relè ausiliario utenza elettrica Sonda ausiliaria Ingresso 1 allarme 230V 50Hz Ingresso 2 allarme ATTENTION the cable length of the auxiliary probe m...

Страница 7: ...hat appears on the display in line with the key N B the first time a key is pressed will have no effect other than turning the display light for it to be seen better primary function 6 function keys secondary function relay ON winter time relay ON summer ambient temperature Celsius Fahrenheit graphic section temperature clock profile messages flat battery symbol day of the week GSM antenna program...

Страница 8: ...s for each half hour however this sequence will be repeated identical every day SEL TEMP PROG DISP JOLLY OFF HOLIDAY ENTER SETTING THE TIME AND DATE 1 After switch on press the PROG key briefly Setup appears then press to access the Hours page Use the and keys to set the hours and then press to set the Minutes 2 Press again to select the Year the Month and the Day in order 3 Press again to select ...

Страница 9: ... the liquid in the heating system from freezing PROGRAMMABLE TEMPERATURES The operating temperature settings can be accessed in the AUTO and HOLIDAY programs Temperatures T1 T2 and T3 can be represented with values ranging from 2 to 40 C The T anti freeze TA temperature can range from 2 to 7 C or be set to OFF that is system off These are the temperatures that can be set when configuring the daily...

Страница 10: ...row to go back to the beginning Consider that T1 will always be less or equal to T2 and T2 of T3 In the JOLLY program the TEMP key alternates the display of the set temperature Tj and the hours left for the program to end these two values can be changed using the and keys In the MAN program you can modify the fixed temperature TMan using the and keys MODIFYING THE DATE AND TIME IN PROGRESS Briefly...

Страница 11: ... temperature profile of the current day to the next day The Correction parameter page is accessed after H profile of the Holiday daily program Use PROG pressed for long or at the beginning of day 1 to go directly to the Correction page From the Correction page onwards use ENTER to exit from the CONFIG menu JOLLY PROGRAM SETTINGS In all programs except MAN the temporary program is selected by press...

Страница 12: ...en 2 0 and 7 0 C with a precision of a tenth of a degree using the and arrows Use the arrow to return to OFF Press OFF again to go back to the previous operating mode ALTERNATIVE DISPLAYS In the AUTO and HOLIDAY programs you can view other information instead of the temperature profile by pressing DISP repeatedly When it is pressed once the temperature set for the current half hour is displayed wh...

Страница 13: ...umbered from 1 to 7 and correspond to the seven days of the week starting with Monday To simplify programming you can set the first day and copy it to the others By default days 1 5 Monday to Friday are 00 00 06 30 T1 06 30 09 00 T2 09 00 11 30 T1 11 30 14 00 T2 14 00 17 00 T1 17 00 22 30 T3 22 30 24 00 T1 whereas days 6 and 7 Saturday and Sunday are 00 00 08 00 T1 08 00 11 30 T2 11 30 23 00 T3 23...

Страница 14: ...s is 00 00 08 00 T1 08 00 11 30 T2 11 30 23 00 T3 23 00 24 00 T1 The value of the temperatures can be set using the TEMP function The profile time variation of the temperatures can be set using the PROG function 8 11 30 23 24h C T3 20 T2 19 T1 17 JOLLY The JOLLY mode allows you to set a temperature Tj for a number of hours 1 to 240 It is used when you want to introduce a temporary change to the pr...

Страница 15: ...aily programs remain unchanged PROGRAMMABLE TEMPERATURES The system requires 4 different temperature levels three for normal use and one called anti freeze to be used when you want to keep the boiler off but without running the risk of the system liquid freezing The programming of the three T depends on the reciprocal values in the sense that T1 cannot be higher than T2 T2 cannot be higher than T3...

Страница 16: ...G THE TEMP KEY In AUTO HOLIDAY and OFF Pressing TEMP will let you access the programming of 4 temperatures that can be used in these conditions Use the and arrows to vary the temperatures while bearing in mind that T1 cannot be higher than T2 T2 cannot be lower than T1 and higher than T3 and T3 cannot be lower than T2 Use the TEMP key to go to the next temperature cyclical T1 T2 T3 Ta TLOW T1 Use ...

Страница 17: ... the minutes cyclically and with you decrease them with you change page with ENTER you exit PROG YEAR YYYY PAG04 Set with you increase the years and with you decrease them with you change page with ENTER you exit PROG MONTH MM PAG05 Set with you increase the months cyclically and with you decrease them with you change page with ENTER you exit PROG DAY DD PAG06 Set with you increase the days cyclic...

Страница 18: ...graph of the temperatures every half hour the indication of the half hour and the associated temperature Day 1 corresponds to Monday and so on Day H is the Holiday which does not vary during the week Use to move a half hour forward Use or to move up or down from tA to t1 to t2 to t3 Use PROG pressed briefly to change the day 1 2 3 4 5 6 7 H Use H to go to page 01 Correction Use PROG pressed for lo...

Страница 19: ... with a set duration between 1 and 29 seconds Use or to switch from OFF to ON and select the duration 1 29 sec Use to go to the next page and ENTER to exit Int Light X PG04 It allows you to change the brightness of the display 9 levels Use or to change the brightness 1 9 Use to go to the next page and ENTER to exit English PG05 It allows you to change the language used for programming Use or to cy...

Страница 20: ...f the programmable thermostat Use to go to the next page and ENTER to exit EXT IN PG12 It allows you to change the management mode of the auxiliary input using the keys and to change non active Connect a probe EC18 EC19 EC20 to set DIS displaying the temperature ADJ adjustment of the ambient temperature by means of the external probe Relay2 SMS PG13 It allows you to use the Relay 2 of CH140GSM for...

Страница 21: ...or the lamp of an aquarium every half hour within 24 hours totally independent from the other functions of the CH140GSM The switch on and off times are set by selecting PRG and pressing the key for the daily profile and the word OFF to be displayed Use and to move a half hour to the right or left Use the and keys to enable ON or disable OFF the relay Use ENTER to go back to page 1 correction which...

Страница 22: ...de before it elapses by setting the number of hours to zero using the arrows and waiting one minute to automatically return to the initial mode or use the SEL key to go to the desired operating mode with the AUTO MAN HOLIDAY OFF cycle USING THE OFF KEY The OFF key allows you to switch the system from any operating mode to off The following window is displayed OFF hour min Tamb The anti freeze temp...

Страница 23: ...owing Fantini Cosmi CH140GSM displayed for a few seconds and then goes into AUTO mode The previous configuration is retained as it is saved in the programmable thermostat The date and time normally remain unchanged If you want to reset the factory settings the system can be restored with the RESET command in PROG CONFIG which exits to the AUTO mode In this case all the settings and customizations ...

Страница 24: ...such as the irrigation via an internal relay The CH140GSM allows a remote user to send an SMS to know what mode the system is in or to control the mode it is to be set in The antenna symbol flashes briefly throughout the management of the remote control as an indication of the relevant response being received and managed IMPORTANT NOTE it is useful to know that the free application IntelliCLIMA is...

Страница 25: ...ent the CH140GSM takes less than a minute to respond with an SMS as follows an example of actual AUTO mode is given REPLY MESSAGE TAMB 22 9 current ambient temperature reading T1 17 0 set temperature T1 T2 19 0 set temperature T2 T3 23 0 set temperature T3 TOFF 5 0 set anti freeze temperature TMAN 16 5 set manual temperature TJOL 19 0 set Jolly temperature HJOL 1 hours of duration of the Jolly pro...

Страница 26: ...message shows PROGRAM MANUAL REMOTE ECONOMY The CH140GSM is in the MAN mode flashing to indicate the remote setting and TMan 17 0 is displayed which coincides with T1 COMFORT command to set the MANUAL mode with TMan the same as T3 present in the status message The reply message shows PROGRAM MANUAL REMOTE COMFORT The CH140GSM is in the MAN mode flashing to indicate the remote setting and TMan 20 0...

Страница 27: ...0 4 The Tens can be omitted e g 9 0 The reply message shows the new value of T2 T3 value Sets the temperature value for T3 The value is written as TU d that is TensUnits decimal e g T3 24 3 The Tens can be omitted e g 9 0 The reply message shows the new value of T3 TMAN value Sets the temperature value for the MANUAL program The value is written as TU d that is TensUnits decimal e g TMAN 22 0 The ...

Страница 28: ...TensUnits e g TIME 12 23 If the Tens are equal to zero they can be omitted e g TIME 12 5 for the time 12 05 MEMO MM Sets the expiry month of the SIM EXP SIM with a 0 12 interval where 0 not set The values are written as TU that is TensUnits e g MEMO 12 for the month of December If the Tens are equal to zero they can be omitted e g MEMO 5 for the month of May The reply message shows the new value o...

Страница 29: ... third telephone number to which only the temperature alarm TLOW SIM expiry and no 230V power or power supply return messages will be sent Replace XXXXXXXXXX with the telephone number that is to be saved N B Max 25 characters You must end the command with an asterisk Important note it is recommended to set your own telephone number in TEL3 to which the alert messages sent spontaneously by the prog...

Страница 30: ...mise the messages concerning alarm1 simply replace INPUT1 with the description of the alarm e g INPUT PORT however no longer than 20 characters and ON OFF with the two conditions e g OPEN CLOSED however no longer than 10 characters each MSGIN2 INPUT2 ON OFF allows you to customise the messages concerning alarm2 simply replace INPUT2 with the description of the alarm e g SHUTTER however no longer t...

Страница 31: ...ower cut POWER ON indicates the 230V power supply return IMPORTANT NOTE it is recommended to set your own telephone number in TEL 3 for the programmable thermostat to spontaneously send alert messages such as TIM expiry and temperature alarm alerts besides the no power and power supply return alerts Example of a temperature alarm alert ALERT TLOW TEMP 11 5 TLOW 12 0 In this case the set threshold ...

Страница 32: ...ctrical insulation double insulation Degree of protection IP20 Pollution degree 2 Pulse voltage 4000V Assembly to the wall Dimensions 137 x90 x 32 mm Quad band EGSM850 900 1800 1900 MHz Output power Class 4 2W for 850 900 MHz Class 1 1W for 1800 1900 MHz Sensitiveness 107dBm 850 900MHz 106dBm 1800 1900MHz Connections Power connector 2 5 mm AWG14 Input Output Connector 2 5 mm AWG14 Conforms to stan...

Страница 33: ...Intellicomfort CH140GSM 33 ...

Страница 34: ......

Страница 35: ...entres The black bar indicates that the product was placed on the market after 13 August 2005 By participating in the separate collection of products and batteries you help with the proper disposal of these materials and therefore help prevent potential adverse consequences for the environment and human health For more detailed information on the collection and recycling programs available in your...

Страница 36: ...82229 export fantinicosmi it www fantinicosmi com FANTINI COSMI S p A Via dell Osio 6 20090 Caleppio di Settala Milano ITALY Tel 39 02 956821 Fax 39 02 95307006 info fantinicosmi it EXPORT DEPARTMENT Ph 39 02 95682229 export fantinicosmi it ...