This bit is normally assigned to a contact with an NC contact.
Measurement error:
The self-diagnosis algorithms have detected a problem in the
measurement block.
Protection error:
The self-diagnosis algorithms have detected a problem in the protection
block.
Setting change:
This activates when the settings are changed.
Date-time adjustment:
This activates when the date-time are synchronised.
Local:
this is the sum of the "HMI activity" and "Local communication" bits from the "Local
communication" status group
Default settings
, the equipment is set to default settings and does not execute the trip.
Eeprom Error:
The self-diagnosis algorithms have detected a problem in the eeprom
memory, which contains the settings.
Eeprom change:
this activates when the settings or configuration are changed. The
settings change which this indication includes are differentiated from the configuration
change, which are also stored in said memory.
Events error:
The self-diagnosis algorithms have detected a corrupt event in the circular
buffer. This bit is reset by deleting the events (from the HMI or by using communications).
HMI Activity:
this condition is active if any key has been pressed in the last 15 minutes.
Pressing a key implies that the relay is in local.
Local control and telecontrol:
It is enabled or there is no telecontrol.
Some states have an event associate with them, which is a register of a change made to
the state. There are states that have an activation event associated with them, and other
states have two associated events: activation and reset. These events are registered in a
circular memory (buffer) with a capacity for up to 200 events. The memory timestamp is
accurate to 1 millisecond.
The events can be browsed from the HMI or by using communications. Reading the
events does not mean that they get deleted, they remain stored on the equipment. To
delete the events using the HMI, you have to go to the events menu and press and hold
the "RESET" key until the number of events reads 1, and this event is registered as
"Events deleted". To delete the events using communications, use the corresponding
"delete events" command.
Operation
Mesaurement error
Protection error
Default settings
Ready
Содержание SIL-V
Страница 7: ...www fanox com Rev 10 7 212 2 DIMENSIONS AND CONNECTION DIAGRAMS 2 1 Equipment front view...
Страница 8: ...www fanox com Rev 10 8 212 2 2 Equipment dimensions...
Страница 9: ...www fanox com Rev 10 9 212 2 3 Cut out pattern...
Страница 11: ...www fanox com Rev 10 11 212 3 VT configuration phase neutral...
Страница 12: ...www fanox com Rev 10 12 212 3 VT configuration phase neutral residual voltage SILVxxxx0xxxxx...
Страница 13: ...www fanox com Rev 10 13 212 3 VT configuration phase neutral busbar voltage SILVxxxx2xxxxx...
Страница 14: ...www fanox com Rev 10 14 212 3VT configuration phase phase residual voltage...
Страница 15: ...www fanox com Rev 10 15 212 2VT configuration phase phase residual voltage...
Страница 17: ...www fanox com Rev 10 17 212 2 5 Terminals...
Страница 25: ...www fanox com Rev 10 25 212 3 3 Functional Diagram...
Страница 192: ...www fanox com Rev 10 192 212...
Страница 210: ...www fanox com Rev 10 210 212 12 9 Comments Person in charge of commissioning Date Maintenance performed on the by...
Страница 211: ...www fanox com Rev 10 211 212 NOTES...
Страница 212: ...www fanox com Rev 10 212 212...