27
Once your ceiling fan is installed in the hanger bracket, slide the receiver into the hanger bracket.
9. INSTALL THE RECEIVER IN THE CEILING HANGER BRACKET
WARNING : Before proceeding to the electrical connections, carefully read the safety instructions in
this manual. Before any electrical connections, switch off all power and restart only when the instal-
lation is completed. Electrical connections must be made in accordance with current regulations and
by a qualified electrician.
Once the receiver is installed in the hanger bracket, make the electrical connections below (see diagram
after) :
1/ CONNECTIONS FROM CEILING FAN TO RECEIVER
- Connect the connector of the ceiling fan (3 wires : pink / grey / red) to the one of the receiver.
2/ CONNECTIONS FROM RECEIVER TO HANGER BRACKET
By using the connecting terminals provided on the hanger bracket :
- Connect the phase of the receiver in the terminal L (LINE : black or brown wire of the receiver).
- Connect the neutral of the receiver in the terminal N (NEUTRAL : blue wire of the receiver).
3/ CONNECTIONS FROM HANGER BRACKET TO AC CEILING POWER
By using the connecting terminals provided on the hanger bracket :
- Connect the phase of the ceiling to the phase of the receiver in the domino L.
- Connect the neutral of the ceiling to the neutral of the receiver in the domino N.
4/ GROUNDING
All ground wires must be connected together and connected to the ceiling ground wire.
10. ELECTRICAL CONNECTIONS