Lumina 71

 

Alarm 

 

 

 

46 

 

 

15. 

 

Alarm 

Request the alarm overview using the alarm key 

There are three tab pages under the alarm key:   

1. 

Overview 

to readout the status. 

2. 

Settings

 to change the alarm settings. 

3. 

History 

to readout the last 20 alarm messages. 

Types of alarm 

There are two types of alarm: 

1. 

LOUD

: A loud alarm means a report is shown on the screen and a siren is sounded (if connected). Take action 

immediately.   

2. 

SILENT

: With a silent alarm (warning), a report will appear on the screen. This type of alarm is usually less 

serious. An active process can be stopped, if required. 

With both types an alarm message will appear on the screen. 

Alarms can be set to 

LOUD

 or 

SILENT

, if required. For nearly all the alarms the user decides the limits outside which 

alarms must be given. 

Alarm statuses 

An alarm can have the following statuses: 

 

ALARM

: Active loud alarm.   

 

WARNING

: Active warning (silent alarm). 

 

OFF FOR ..:..

: The user has noticed the alarm; the alarm situation is still present. 

 

RECOVERED

: The control computer has automatically recovered the alarm; the alarm situation is no longer 

present. 

Alarm history 

As soon as the control computer gives an alarm, the alarm is included in the alarm history. The last 20 alarms with 
corresponding dates and times can be readout on tab page 

History

15.1

 

Dealing with alarms 

15.1.1

 

Dealing with a LOUD alarm 

If the alarm system is active and a LOUD alarm occurs, the siren will activate and the LED near the alarm key will 
flash red.   

1.  Press once on the alarm key to display the alarm message on the screen. The siren will fall silent at the same 

time. 

2.  Then press - within one minute - once more on the alarm key to change the alarm status from 

ALARM 

to 

OFF 

for 00:15

. This means the alarm has been noticed, but the alarm situation is still present! For the next 15 

minutes the computer will not give an alarm again for this situation. A new alarm will only be given if the alarm 
is briefly within, then outside the alarm limits in this 15 minute period. This time can be adjusted for alarms that 
require more time to be remedied. 

 

If you do 

not

 press the alarm key 

again 

within 1 minute, the alarm will reactivate. In this case, start again 

at step 1 to switch off the alarm. 

Содержание LUMINA 71

Страница 1: ...LUMINA 71 LUMINA 71 LUMINA 71 TOUCH F71 USER MANUAL VERSION D1 g ...

Страница 2: ...ed by Fancom For the latest information about product installation and operation please contact the customer service dept and or the technical service dept of the Fancom company concerned In spite of the care taken when compiling this manual if you should discover any errors please inform Fancom B V in writing Fancom B V PO Box 7131 5980 AC Panningen the Netherlands Copyright 2013 Fancom B V Panni...

Страница 3: ...mputer 11 4 1 Main menu 11 5 Process overview 12 5 1 Overview 12 5 2 Weigher 12 5 3 Transport 13 5 4 Time clock 14 5 5 Manual 14 5 6 Process 15 6 Feed feeding place 17 6 1 Overview 17 6 2 Curve FP 17 6 3 Set FP 18 6 4 Dose 20 6 5 Section 20 6 6 Copy 22 7 Silo and Feed 23 7 1 Silo overview 23 7 2 Ingredient overview 24 7 3 Bulk 25 8 Time clock 26 8 1 Overview 26 9 Registration general 27 9 1 Ingred...

Страница 4: ...es 39 13 2 Time and date 40 13 3 Start feed cycle 41 14 Registration feed place 42 14 1 Overview 42 14 2 Overview EV 42 14 3 History 43 14 4 Section FP 43 14 5 Ingredient 44 14 6 Animal 44 15 Alarm 46 15 1 Dealing with alarms 46 15 2 Deactivating the alarm system 47 15 3 Testing the alarm system 47 15 4 System alarms ERROR nn 47 15 5 Alarm overview 48 ...

Страница 5: ...te manual This manual also applies to other control computers in the Fancom F2000 line Always read the safety instructions and warnings carefully before using the control computer Always keep this manual close to the control computer 1 2 How to use this manual The following symbols are used in this manual Tips and suggestions Note providing recommendations and additional information Warning indica...

Страница 6: ...ch between sections and feed places It is e g used to set up animals per section or per feed place 1 5 Fancom helpdesk For any questions and support please contact the local Fancom Sales Service Center 1 6 F Central FarmManager Virtually all Fancom equipment can be controlled and managed from a central location This requires the F Central FarmManager software package and a communication module The...

Страница 7: ...nd amount are based on the animals life cycle If the feed composition is changed a gradually transition will take place from one type of feed to the next The figure below shows a feed installation with a transport route and circuit The feed is placed on the route circuit from the weigher blender and transported to the feed place By opening the right feed valve feed is released into the relevant tr...

Страница 8: ...Lumina 71 Overview 4 Figure 2 Example route dry feeding system ...

Страница 9: ...Lumina 71 Overview 5 Figure 3 Example route system ...

Страница 10: ...ust like the Dosing method a fixed amount of feed is supplied per feeding cycle If this exceeds the trough capacity the control computer will regularly check if the trough sensor is uncovered More feed can be supplied until the total feed amount has been reached Select the required feeding method when setting up the animals Set and change the feeding method per feed place 3 2 Feed curves Curves al...

Страница 11: ... days 7 14 21 28 etc Bending point 2 3 Curve day 7 8 9 10 11 12 13 14 Curve daily amount per animal 1 000 1 050 1 100 1 150 1 200 1 250 1 300 1 350 The control computer takes the feed amounts on days 7 and 14 from the feed curve and calculates the feed amounts for the days between The feed amount increase in steps For a feed place with 10 animals the daily amount in the curve is 10 The description...

Страница 12: ...rter feed percentage is reduced and the transitional feed percentage is increased During the transition from starter feed to transitional feed the system adjusts the feed composition from day to day From day 40 onwards only transitional feed is supplied The table below is based on the figure and shows the feed composition during the life cycle Feeding days Feed composition 1 21 100 starter feed 22...

Страница 13: ...he clock The dotted line indicates the current time The control computer determines the calculated feeding cycle amount by dividing the calculated daily amount by the number of feeding cycles Calculated feeding cycle amount Calculated daily amount Number of feeding cycles Number of animals at the feed place 10 Amount per animal 0 8 kg Total 10 0 8 8 kg If 2 feeding cycles are used 4kg will be supp...

Страница 14: ...culate the feeding cycle amount or composition For example A feed curve currently being used at a feed place is changed The feed composition at the feed place is changed The dosing percentage is changed as shown in the above example The number of animals at the feed place is changed e g by registering mortality The biorhythm is changed The following situations can occur Changing the feed data for ...

Страница 15: ... 11 4 Control computer 4 1 Main menu The Lumina 71 controller displays standard the main menu Overview Lumina 71 This screen is the starting point for the operation via the Lumina 71 controller Process overview tab page Overview ...

Страница 16: ...Silo Readout of the ingredient in the silo Weigher Readout of the feed place at which the blend would be dosed out Readout of the blend that is in the weigher Readout of the blend status ON OFF Readout of the amount of blend in the weigher kg Hopper Readout of the feed place at which the blend is currently being dosed out Readout of the number of feed columns in the Circuit Active feed cycle Reado...

Страница 17: ...ntly being fed If the current ingredient is a replacement ingredient the name of the original ingredient appears between brackets From silo Readout of the silo from which feed is being supplied Dosing in status This function is only used by Fancom Dosing out status This function is only used by Fancom Number of feed columns on the way This function is only used by Fancom Feed places in weigher Thi...

Страница 18: ...column Clock status Readout of the status of the feed clock ON OFF right hand column 5 5 Manual Process overview tab page Manual Feed process Readout of the current feed process status IS ACTIVE or IS NOT ACTIVE Feed process status Readout of the current status of the feed process BLOCK FREE and BLOCKED EMER STOP Manually feeding Setting if you want to feed a feed place or section Section Feed pla...

Страница 19: ... amount Setting of the feed amount that would be transported to the feed place 5 6 Process Process overview tab page Process Feed process Readout of the current feed process status IS ACTIVE or IS NOT ACTIVE Feed process status Readout of the current status of the feed process BLOCK FREE and BLOCKED EMER STOP Interrupt the feed process as follows Select one of the following options depending on th...

Страница 20: ...en interrupted it can be resumed Select one of the following options depending on the feed process status Start If the process status is READY or ENDED Continue If the process status is EMERGENCY STOP or STOPPED Release If the process status is BLOCK Reset After an emergency stop or if the feed process is not active Only use the reset option in emergencies Read the instructions on the display befo...

Страница 21: ...he feed place The control computer updates the data after every day change This means that the current situation for the following days is shown every day To dos Readout of the feed amount today Dosed Readout of the feed amount that already dosed out today Status S F Readout of the feed place status BLOCK FREE BLOCK If sensors are used readout of sensor S or feedplace F status 6 2 Curve FP This ta...

Страница 22: ...daily energy value EV per animal This is the daily feed amount corrected by the dosing percentage Cycle Readout of the actual number of feed cycles Price Readout of the total price of the blend EV Blend Readout of the total energy value of the blend Ingred01 20 Setting of the amount per ingredient in the composition at this bending point Changing the feed composition affects the feed composition o...

Страница 23: ...ethod Setting of the feeding method REGISTER DOSING DOSE REGIST Day Am Setting of the feed amount that will be dosed this day The value between the brackets indicates the actual dosing percentage Sensor status Readout of the current sensor status Am Anim Readout of the calculated daily amount per animal This amount is based on the dosing percentage After adjusting Day Am the dosing percentage will...

Страница 24: ...uction days Variable Setting to change the dosing percentage to a variable The control computer gradually brings the difference back to 100 The difference is smaller each day If both types of difference are combined the fixed difference will be applied first the difference remains the same for a number of days The variable difference will be applied next the difference will gradually be restored t...

Страница 25: ... of the animal weight Feeding method Setting of the feeding method REGISTER DOSING DOSE REGIST Day Am Setting of the feed amount that will be dosed this day The value between the brackets indicates the actual dosing percentage Am Anim Readout of the calculated daily amount per animal This amount is based on the dosing percentage After adjusting Day Am the dosing percentage will be automatically re...

Страница 26: ... saves a lot of time Feed feeding place tab page Copy Copying data In this tab page you can copy data of a certain feed place to a number of other feed places First set the feed place which you want copy data from Then select the data you want to copy YES NO Set the range of feed places you want to copy data to and finally click on Ready to copy the data ...

Страница 27: ...upply and consumption may differ due to the error margin of weighing and dosing in equipment A negative stock may occur for example if the bulked stock has not yet been registered in the control computer Silo status Readout of the silo status CURRENT Select this silo as the standard silo for dosing out the feed ingredient If it does not hold enough of the ingredient for dosing in the control compu...

Страница 28: ... ingredient If a feed ingredient runs out during a feeding cycle the control computer will use the alternative feed ingredient for the rest of the feeding cycle At the next feeding cycle the control computer will first check that the original ingredient is available again Mix during dosing in Setting if the blender is activated while the blend is ingredient been dosed in YES NO Blender off at Kg b...

Страница 29: ...ion Silo Set in this chapter Ingredient Setting the ingredient used for bulking Amount Setting of the amount to be bulked Price KG Setting of the price per kilogram of the amount to be bulked Energy value EV Setting of the energy value EV of the amount to be bulked Date Setting of the bulking date After bulking the new stock can be registered The control computer re calculates the average price an...

Страница 30: ...g the end time of the time clock Status Setting of the time clock status FREE The control computer can run the time clock BLOCKED The control computer will skip the time clock ONCE The time period will be run once on the next occasion that the on time of the time period is reached Afterwards the control computer sets the status to BLOCK SKIP The time period will be skipped next time Afterwards the...

Страница 31: ...ngredients Registration general tab page Ingredient Ingredient Readout of the name of the ingredient Today Readout of the amount of ingredient used today Yesterday Readout of the amount of ingredient used yesterday Total Readout of the total amount of ingredient Costs Total Readout of the total ingredient costs Those costs are based on the price per kilogram ingredient entered at bulking see Silo ...

Страница 32: ...us registration for example to register gas or electricity consumption Registration general tab page Reg input Reg input Readout of the name of the registration group Today Readout of the total consumption today Yesterday Readout of the total consumption yesterday Total Readout of the total consumption ...

Страница 33: ...ered by the control computer Bulking may have occurred again in the meantime without this having been entered in the control computer Set alarm tab page Ingred Ingredient Name Readout of the name of the ingredient Minimum stock Setting of under which amount kg of ingredient the control computer gives a Minimum stock warning 10 2 FP Cons Only available with sensor feeding Set alarm tab page FP Cons...

Страница 34: ...Lumina 71 Set alarm 30 10 3 External input Set alarm tab page Ext inp Description Readout of the name of the external input Alarm Setting which alarm the control computer gives NONE LOUD SILENT STOP ...

Страница 35: ...of the number of animals present Set up Readout of the number of set up animals Mortality Readout of the number of animal mortality Readout of the number of animals the controller has add to the feed place Readout of the number of animals the controller has moved from the feed place Delivered Readout of the number of delivered animals When setting up animals the control computer places all old val...

Страница 36: ...out of the number of moved animals from this feed place and readout of the date of the last change Tot delivered Readout of the number of delivered animals Set up Readout of the number of set up animals And readout of the date the animals were set up on Set up weight Readout of the average animal weight that has been set up kg 11 3 Set up Animals feed place tab page Set FP Set up for feed place Se...

Страница 37: ...feed place Adjustment days fixed Setting of the fixed correction of the dosing percentage Adjustment days variable Setting of the variable correction of the dosing percentage Also at feed place Setting of the feed place the data have been copy from Thru feed place Setting of the feed place the data have been copy to After setting up the feed place status automatically changes to FREE 11 4 Mortalit...

Страница 38: ...rhythm etc The new feed place adopts the feed curve and feeding cycles of the old feed place provided there are no animals present at the new feed place Weight per animal Setting of the animal weight If animals are already present at the new feed place the control computer will not use the curve day at the new feed place The control computer uses this to calculate the curve day and total weight To...

Страница 39: ...not already been done Nbr of animals Setting of the number of animals delivered Weight per animal Setting of the weight per animal kg Total weight Setting of the total weight of the animals delivered kg Date Readout of the date the animals were deliver The control computer uses the delivery date to update all historical data A future delivery cannot be entered by using a future delivery date A del...

Страница 40: ... curve tab page Overview Curve Readout of the number of the feed curve Description Readout of the selected feed curve name 12 2 Curve Feed curve tab page Curve Curve name Readout of the selected feed curve name Bendpoint Readout of the bendpoint from the feed curve Curve day Setting the day on which the new feed composition becomes fully effective Always use Curve day 1 for the first bending point...

Страница 41: ... to be supplied per feeding cycle must never exceed the trough capacity at the feed place Keep this in mind when using the DOSING method If 12 kg of feed per feeding cycle for example is to be given the trough must be able to hold this amount If the trough content is only 10 kg 10 kg will be supplied per feeding cycle 2 less than required Price Readout of the feed price per kilogram The control co...

Страница 42: ... Copy from Setting of the feed curve the data have been copy from To Setting of the feed curve the data have been copy to Enter curve name Setting of the name of the new feed curve If you already have set a curve this curve would be overwriting during copying ...

Страница 43: ... Overview feed cycles Enter the required feeding cycles per feed curve The control computer divides the amount to be fed among these feeding cycles every day Enter the feeding cycles in chronological order The feeding cycles are shown in the time bar at the bottom of the screen The current time is indicated by a vertical dotted line Feeding cycles cannot overlap Feeding cycles tab page Overv Feed ...

Страница 44: ...e Setting of the time of the day change Many tasks depend on a day change such as starting feeding cycles or time clocks and data registration The day change is used as follows Daily data registration Each day begins and ends at the time of the day change If the last feeding cycle is still active when the day change is reached the control computer will not interrupt this feeding cycle The day chan...

Страница 45: ... run immediately and not during the time period of the feeding cycle The feeding cycle will be run for all the relevant feed places If the first next feeding cycle is after the next day change it cannot be started manually Feeding cycles tab page Start feed cycle Start feed cycle Setting of the feed cycle that you want to start directly ...

Страница 46: ...ngredient used today Yesterday Readout of the total consumption yesterday Total Readout of the total consumption 14 2 Overview EV This tab page shows consumption per feed place and per animal based on the energy value EV Registration feed place tab page Ovw EV EV Readout of the name of the feed place Today Readout of the total energy value EV used today Yesterday Readout of the total energy value ...

Страница 47: ...t of the average amounts per animal Fed Readout of the total feed amount that has been dosed out EV Readout of the total energy value that has been dosed out Costs Readout of the total ingredient costs Those costs are based on the price per kilogram ingredient entered at bulking see Silo and Feed page 23 The Costs Total can be set to zero manually Animal days Readout of the number of days the anim...

Страница 48: ...of the amount of ingredient used today Total Readout of the total amount of ingredient 14 6 Animal Registration feed place tab page Animal Delivered Readout of the total number of animal delivered at this feed place Delivered weight Readout of the average weight of the delivered animals kg Delivery Date Readout of the date the animals were deliver The control computer uses the delivery date to upd...

Страница 49: ...costs are based on the price per kilogram ingredient entered at bulking see Silo and Feed page 23 The Costs Total can be set to zero manually EV Readout of the total energy value that has been dosed out Set up date Readout of the last date the animals were set up on Total set up weight Readout of the average animal weight that has been set up kg Mortality Readout of the number of animal mortality ...

Страница 50: ...r has automatically recovered the alarm the alarm situation is no longer present Alarm history As soon as the control computer gives an alarm the alarm is included in the alarm history The last 20 alarms with corresponding dates and times can be readout on tab page History 15 1 Dealing with alarms 15 1 1 Dealing with a LOUD alarm If the alarm system is active and a LOUD alarm occurs the siren will...

Страница 51: ...as been deactivated If the alarm system is deactivated the control computer will not generate any alarm messages except system alarms Never switch the alarm system off during regular operation Deactivate the alarm system as follows 1 Press the alarm key 2 Change the Alarm system status to OFF The screen shows that the alarm system has been deactivated A corresponding alarm message will also appear...

Страница 52: ...oes not increase sufficiently so the weighing process cannot be continued Name ingredient TOO MUCH L During dosing in too much ingredient Name ingrd REPLACE S Replace ingredient by substitute ingredient SILO NOT SWITCHING S The silo does not open when dosing in WEIGHER MAX TARE L The maximum tare of the weigher has been exceeded WEIGHER MAXIMUM L The maximum weigher content has been exceeded FP na...

Страница 53: ...t closed entered text will appear Assign IO L The IO address is not suitable for this hardware e g address 0 13 for IOB 4 Circuit alarms Report Type Description NO PULSES circuit Number L No circuit pulses are reported back Overflow FP number S The control computer has detected feed in the overflow hopper for the listed valve number Overflow CIRC Number L The control computer has detected feed in ...

Отзывы: