Lumina 47
Technical specifications
24
6.
Technical specifications
FDP25
Mains voltage
90Vac – 264Vac
Main frequency
50/60Hz
Maximum power consumption
25VA
IOB.0
Power available for sensors and peripheral equipment
24Vdc (short circuit resistant)
max. 500mA
1 Digital output (Relay)
Relay 1 (alarm relay): voltage free
max. 2A 60Vdc/30Vac
Communication
I/O-Net for extra inputs and outputs using I/O-modules.
FNet, Fancom network for intercommunication of control computers and PC connection.
LCC
Excitation voltage
5 Vdc
2 × Max. input signal
78 mVdc
Max. load
8x350
Ω
Cable length
Max. 50 m
Housing
Plastic housing with screw-on lid
IP54
Dimensions (l×w×h)
300×240×140mm
Weight (unpacked)
2.6kg
Ambient climate
Operating temperature range
0
°
C to +40
°
C
Storage temperature range
–10
°
C to 50
°
C
Relative humidity
< 95%, uncondensed