Gnd
4
g
Set the I/O address
Using the table below, set the I/O address with the dipswitches 1 thru 5.
In an I/O network, all IMS units must have a unique address.
I/O address
Temperature measu position feedback
I/O
adrr.
DIP
1
DIP
2
DIP
3
DIP
4
DIP
5
DIP 6
On (IMS doesn't measure the temperature)
Off (IMS measures the temperature)
AN
On
On
On
On
On
DIP 7
On (CPS - contactless position sensor)
Off (potentiometer)
1
Off
On
On
On
On
DIP 8
On (default direction of rotation)
Off (inverse direction of rotation)
2
On
Off
On
On
On
3
Off
Off
On
On
On
4
On
On
Off
On
On
5
Off
On
Off
On
On
6
On
Off
Off
On
On
7
Off
Off
Off
On
On
8
On
On
On
Off
On
9
Off
On
On
Off
On
10
On
Off
On
Off
On
11
Off
Off
On
Off
On
12
On
On
Off
Off
On
13
Off
On
Off
Off
On
14
On
Off
Off
Off
On
15
Off
Off
Off
Off
On
16
On
On
On
On
Off
17
Off
On
On
On
Off
18
On
Off
On
On
Off
19
Off
Off
On
On
Off
20
On
On
Off
On
Off
21
Off
On
Off
On
Off
22
On
Off
Off
On
Off
23
Off
Off
Off
On
Off
24
On
On
On
Off
Off
25
Off
On
On
Off
Off
26
On
Off
On
Off
Off
27
Off
Off
On
Off
Off
28
On
On
Off
Off
Off
29
Off
On
Off
Off
Off
30
On
Off
Off
Off
Off
31
Off
Off
Off
Off
Off
19
Off
Off
On
On
Off
20
On
On
Off
On
Off
21
Off
On
Off
On
Off
22
On
Off
Off
On
Off
23
Off
Off
Off
On
Off
24
On
On
On
Off
Off
25
Off
On
On
Off
Off
26
On
Off
On
Off
Off