Lumina 750
Classic screens
21
à
Sub-phases
à
Disinfection
Time
Setting of how long (hours and minutes) the disinfection sub-phase should last.
Time remaining
Readout of the remaining time (hours and minutes) of the disinfection phase. During
disinfection this time can be changed or set to 0. In this case the disinfection period
will be ended.
Circulation
Setting of the fan speed (% or m
3
/hour) which applies during the disinfection phase.
The sub-phase indication light lights up every second when disinfecting the tunnel.
21
à
Sub-phases
à
Filling
Time
Setting of how long (hours and minutes) the filling sub-phase should last.
Time remaining
Readout of the remaining time (hours and minutes) of the filling sub-phase. During
filling this time can be changed or set to 0. In this case the filling sub-phase will be
ended.
Circulation
Setting of the fan speed (% or m
3
/hour) which applies during filling.
Fresh air
Setting of the required fresh air inlet position in % or the amount of fresh air in m
3
/
hour, which must be reached by the Lumina 750 during filling.
Exhaustvalve
Setting of the exhaustvalve (%) during filling.
Circ. alarm
Setting of circulation alarm during filling.
Abs. Ct. alarm
Setting of absolute compost temperature alarm (temperature in °C/°F). During the
sub-phases Filling and Empty, the tunnel temperature should not exceed this. If it
does for longer than three hours, an alarm is activated.
The sub-phase indication light lights up every 2 seconds when filling the tunnel.
55