Lumina 750
Using the Lumina 750
à
Dial
Readout of the average compost temperature (°C /°F). Faulty sensors and sensors
showing a too great deviation are not used for this calculation.
●
The control computer will automatically set sensors showing a temperature
that differs too much from the previous average temperature (more than the
maximum deviation) to non-active. These sensors will have to be re-activated
manually if they are to be included in the calculation of the
Average compost
temperature
.
●
The computer will reactivate all non-active sensors after the
EMPTY
phase
(phase 0).
If there are only two sensors remaining to calculate the
Average compost
temperature
, the computer will only de-activate them if they are faulty.
Readout of the current compost temperature control value (°C /°F). At the beginning
of each growing phase the control value is automatically set to the
Average
compost temperature
. The control computer will gradually regulate the compost
temperature towards the
Compost temperature end value
.
Readout of the lowest measured compost temperature (°C /°F) from sensors that
are included in the calculation of the
Average compost temperature
.
Readout of the highest measured compost temperature (°C /°F) from sensors that
are included in the calculation of the
Average compost temperature
.
Setting of the end temperature of the compost (°C /°F). The control computer will
gradually regulate the
Compost temperature control value
towards the end value.
Setting of the adjustment speed of the
Compost temperature control value
(°C/hour
or °F/hour).
3.1.8
O2 control
Classic O
2
control settings: Function key 4: O2/CO2/NH3 (page 40).