Lumina 750
Basic working principles
70 (158)
60 (140)
50 (122)
40 (104)
30 (86)
20 (68)
10 (50)
6
12
18
24
30
36
42
48
54
Temperature °C (°F)
Time (hours)
Warm up cook out
Natural
cool down time
Max. phase time cool down
cook out
Empty
Cook out
Phase
13
Phase
14
Phase
15a
Phase
15b
Phase
0
Measured compost temperature
Measured air temperature
Figure 6: Compost and air temperature during cook out
phase 13
The fan is activated and the air inlet is closed (warm up).
phase 14
The fan is activated and the air inlet is closed. This period lasts e.g. 12 hours
phase 15a
The fan is
activated
or
deactivated
and the air inlet is closed (natural cooling). This
period lasts e.g. 6 hours (extra time setting).
phase 15b
The fan is activated and the computer controls the air inlet based on temperature (if
set). This period equals the time remaining for cool down. At the start of the period
cooling had already been active for 6 hours; there are 30 hours remaining for this
period.
phase 0
The fan is deactivated and the tunnel is closed.
2.6
Working per sub-phase
2.6.1
SUB-PHASE: Cleaning
Aim
Cleaning the tunnel after using chemical disinfectants.
Uses
●
fan
●
fresh air
Method
The cleaning sub-phase can be used only during the empty phase. This sub-phase can be
started/stopped by pressing the cleaning button. The cleaning button is an external button
placed outside of the controller. The subphase can also be started by entering the required
subphase at
1
Overview
-
Sub-phase
.
12