background image

Fancom 743 

INSTALLER:   5. System settings 

 

 

5

 

5.

 

System settings  

 

5.1

 

General 

 

The system settings are intended for the installer. Normally the user will never have to change 

these settings, with the exception of the password. 

 

The system settings are not for daily use. The installer makes these settings when the weighing 

computer is installed. All system settings are protected by a  password. The password is a 

combination of maximum five function keys.  As long as the password is unchanged, this is key 

. Chapter 7 in the user manual describes how to change the password. 

 

The system settings are divided into three groups:  

 
    

     

 

                                                                                                                                                                                        

 

 

 

 

 

 

 

1 Configuration 
2 Installation 
3 Internal RAM 
 

Содержание 743

Страница 1: ...GB 743 INSTALLER MANUAL VERSION C3...

Страница 2: ...to the original purchase price to the original purchaser in lieu of such repair or replacement Labour costs associated with the replacement or repair of the product are not covered by the Manufacturer...

Страница 3: ...stallation 4 5 System settings 5 5 1 General 5 5 2 Configuration 6 5 2 1 General 6 5 2 2 Communication 7 5 3 Installation 8 5 3 1 General 8 5 3 2 Silo 9 5 3 3 Additive 9 5 3 4 Weigher 10 5 3 5 Circuit...

Страница 4: ...al is also available for the user The user s manual contains information about the daily use of the computer If you have any questions regarding the computer please do not hesitate to contact your Fan...

Страница 5: ...ding proximity switch 16 storage silos incl prox feedback 4 additives 2 circuit auger controls 16 storage silo selection valves 16 storage silo augers 16 feed clocks 16 water clocks 16 pulse inputs fo...

Страница 6: ...z 1 Weigher input resolution 12 bits not for commercial purposes Excitation 10Vdc Max input voltage 20 mVdc Max load 2 350 weighing bar Max cable length 40 m Housing Plastic housing with screw on lid...

Страница 7: ...ng the computer it is advisable to mount a 4 x 4 wireway below the computer Two 1 conduits running between the computer and the wireway should be used one for high voltage wire rights side and one for...

Страница 8: ...ure that the gland nuts are at the bottom of the computer 6 Use gland nuts for the connection of the computer Use the sealing plates supplied to seal the gland nuts which are not used Seal all gland n...

Страница 9: ...settings are not for daily use The installer makes these settings when the weighing computer is installed All system settings are protected by a password The password is a combination of maximum five...

Страница 10: ...ers enter whether this should take place every 16 minutes or once a day This should also be entered for the slaves They will adopt the time from the master Unit temp Enter the unit of temperature C de...

Страница 11: ...nication counters with loop communication for receive Receive and transmit Transmit These counters can be used to trace faulty communication connections In this case set all the counters on all the co...

Страница 12: ...ten groups External alarm Enter the address in front of the point and the digital input number behind the point to which the external alarm has been connected Day change Enter at what time a day peri...

Страница 13: ...an still fall into the weigher after flow This after flow is a computer calculated value When the 743 is started the after flow is 0 0kg Enter an estimated after flow for the first time the 743 is put...

Страница 14: ...a valve motor controlled in two directions WHOP RIN Standing steel weigher with a valve controlled by a solenoid rinse control OUT AUG Dosing out auger direct from the weigher Weigher tare The weight...

Страница 15: ...imum sensor has been connected Min sensor Enter the address in front of the point and the digital input number behind the point to which the minimum sensor has been connected Empty hopper Enter within...

Страница 16: ...e pressure of feed in the weigher decreases the feed column will be spread more thinly over the auger This means that the column will become longer resulting in an increased transport time to the stor...

Страница 17: ...e valve needs to open or close fully Auger aft run Enter how long minutes and seconds the storage silo auger must continue running after the feed has passed the reverse valve 5 Storage silo 1 Circuitn...

Страница 18: ...and the relay number behind the point to which the storage silo auger control has been connected Status The current storage silo auger status ON storage silo auger running or OFF storage silo auger i...

Страница 19: ...tration mode is used In this case the day amount is unlimited but the batch size is variable smaller batches for young animals Example Weigher capacity 2000kg Feed amount according to norm 20 000 chic...

Страница 20: ...ot active Unit pulse Enter how much water litres corresponds to one water pulse 5 3 9 Light clock Relay output Enter the address in front of the point and the relay number behind the point to which th...

Страница 21: ...dress in front of the point and the relay number behind the point to which the time clock control has been connected Status The current time clock status ON time clock active or OFF time clock not act...

Страница 22: ...f and on and check for correct functioning 102 Communication alarm Communication between the Master and the Slave s has been interrupted for a length of time Check wiring and communication settings 10...

Страница 23: ...figuration 2 Installation 3 Internal RAM 1 Configuration 1 General Setting Sec New password 5 2 1 Time 5 2 1 Date 5 2 1 Synchr time 5 2 1 Unit temp 5 2 1 Unit windspeed 5 2 1 Version 743 5 2 1 1 Confi...

Страница 24: ...ting Sec Weigher content 5 3 4 Valve status 5 3 4 Motor control 5 3 4 Weigher type 5 3 4 Weigher tare 5 3 4 Capacity 5 3 4 Address ILM 5 3 4 Counts 5 3 4 Zero offset 5 3 4 Span 5 3 4 Filter 5 3 4 Stab...

Страница 25: ...3 6 Am feed pulse 5 3 6 Tolerance 5 3 6 Batch am 5 3 6 Max Batch 5 3 6 Min Batch 5 3 6 Release house 5 3 6 Status 5 3 6 2 Installation 6 Storage silo 9 10 11 12 13 14 15 16 Sec Circuit number 5 3 6 Po...

Страница 26: ...ock 9 10 11 12 13 14 15 16 Sec Pulse input 5 3 8 Relay output 5 3 8 Status 5 3 8 Unit pulse 5 3 8 2 Installation 9 Light clock 1 2 3 4 5 6 7 8 Sec Relay output 5 3 9 Status 5 3 9 Analog output 5 3 9 T...

Страница 27: ...ransport point reports empty This can be either a weigher or a weighing hopper max 16 Important setting System 2 Installation 6 Storage silo Auger after run III Circuit with storage silo selection val...

Страница 28: ...Fancom 743 APPENDIX 4 Connection diagrams...

Страница 29: ...Fancom 743 APPENDIX 4 Connection diagrams...

Страница 30: ...Fancom 743 APPENDIX 4 Connection diagrams...

Страница 31: ...Fancom 743 APPENDIX 4 Connection diagrams...

Отзывы: