INSTALLER: 5. System settings
16
5.3.8
Water clock
Pulse input
Enter the address (in front of the point) and the digital input number (behind
the point) to which the water pulse counter has been connected.
Relay output
Enter the address (in front of the point) and the relay number (behind the
point) to which the water clock control has been connected.
Status
The current water clock status: ON (water clock active) or OFF (water clock
not active).
Unit/pulse
Enter how much water (litres) corresponds to one water pulse.
5.3.9
Light clock
Relay output
Enter the address (in front of the point) and the relay number (behind the
point) to which the light clock control has been connected.
Status
The current light clock status: ON (light clock active) or OFF (light clock not
active).
Analog output
Enter the analog output number to which the light clock analog control has
been connected.
Type
Enter the type of analog control: 0-10V or 10-0V.
>>Water clock
1
Pulse input 0. 0
Relay output 0. 0
Status OFF
Unit/pulse 0.0
7×
>>Light clock
1
Relay output 0. 0
Status OFF
Analog output 0
Type 0-10V
8×