10
SAFETY DEVICES ON THE COOKER
Safety shutdown
If a cooking area exceeds the maximum time for operation at the same power, it is auto-
matically switched off and the indication of the residual heat is shown.
To reset the cooking area, touch the necessary keys.
Power level
low
1
2
3
4
5
6
7
8
9
P
Maximum
duration of
operation in
hours
8.7 2.0 8.7 6.7 5.3 4.3 3.5 2.8 2.3 1.9 1.5
The cooker switches off automatically if one or more controls stay covered for more than
10 seconds.
To restore the proper operation:
- remove all objects from the control panel.
- clean the control panel.
- restart the cooker and the concerned area.
Overheating device
Before items of the cooker can overheat, the control reduces the used power by follow-
ing this procedure for protection measures:
- Deactivation of booster and power booster if turned on.
- Reduction of the power level set.
- Shutdown of the cooking area concerned.
On the display of the cooking area the message “E2” is displayed.
It is possible to restore the cooking area when the default message is off.
ELECTRICAL SAFETY
The electrical system to which the cooker is to be connected must be in
accordance with local standards and supplied with earthed connection in
compliance with safety regulations in the country of use. It must also com-
ply with European standards regarding radio antistatic properties.
Make sure that it can’t be possible to touch the power cable of the cooker after it has been
built-in and that it is not subject to mechanical stress.
The socket used to connect the installed equipment to the electrical power supply must be
within reach: otherwise, install a mains switch to disconnect the machine when required.
Any changes to the electrical system must be carried out by a qualified electrician.
Do not try to solve the problem yourself in the event of equipment malfunction, but contact
the Dealer or an authorised Servicing Department for repairs.
When installing the cooker, disconnect the equipment by removing the
plug or switching off the main switch.
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
ELECTRICAL CONNECTION
(only intended for qualified personnel)
Disconnect the equipment from mains power network before carrying out
any operation on the cooker.
Make sure that electric wires inside the cooker are not disconnected or cut:
in the event of damage, contact your nearest Servicing Department.
Refer to qualified personnel for electrical connections.
Connection must be carried out in compliance with the provisions of law in force.
Before connecting the cooker to the mains power network, check that:
• the mains voltage corresponds with the voltage indicated on the data plate located
inside the cooker;
• the electrical system is compliant and can withstand the load (see the technical specifi-
cations located inside the cooker);
• the power supply plug and cable do not come into contact with temperatures exceed-
ing 70 °C;
• the power supply system is effectively and properly connected to earth in compliance
with regulations in force.
• the socket used to connect the cooker is within reach.
In case of:
• devices fitted with cables without a plug: the type of plug to use is a ''standardised'' one.
The wires must be connected as follows: yellow-green for earthing, blue for neutral and
brown for the phase. The plug must be connected to an adequate safety socket.
• fixed equipment not provided with a power supply cable and plug, or any other device
that ensures disconnection from the electrical mains, with an opening gap of the con-
tacts that enables total disconnection in overvoltage category III conditions.
Said disconnection devices must be provided in the mains power supply in compliance
with installation regulations.
The yellow/green earth cable must not be cut off by the switch.
The Manufacturer declines all responsibility for failure to comply with the safety regulations.
Connection of the cooker
network
Connection
Cable
section
Power
cable
Switch
gauge
220V - 240V~
50/60Hz
1P+N / 2P
3 x 2.5 mm²
H 05 VV - F
H 05 RR - F
25 A *
380V - 415V~
50/60Hz
2P+N
4 x 1.5 mm²
H 05 VV - F
H 05 RR - F
16 A *
380V - 415V~
50/60Hz
3P+N
5 x 1.5 mm²
H 05 VV - F
H 05 RR - F
16 A *
* calculated with the contemporary factor in compliance with EN 60 335-2-6.
POWER:
Total power
7400W
Position 1
Rated power
2100W
Booster power
3700W
Position 2
Rated power
2100W
Booster power (1/2)
3700W
Position 3
Rated power
2100W
Booster power (1/2)
3700W
Position 4
Rated power
2100W
Booster power
3700W
Содержание Modula M1
Страница 31: ...31 2 13...
Страница 32: ...32 8 1 5 70 C...
Страница 33: ...33 III 800 3 4 4 x 10 5 15 1 3 4 5 6 7 8 P 30 3 4 A M3 1 9 P P 9 P 1 TIMER 15 TIMER 4s 4 30 5 2000 5 3...
Страница 34: ...34 15 Magic Steel F 1 55 C F 1 2 18 3 12 A B C 200 C 2 4 RAEE RAEE x1...
Страница 43: ...43 NOTE NOTES...
Страница 77: ...33 8 Falmec BRIDGE 5 PowerFlex...
Страница 81: ...37 5 1 2 2 6 E 10 Basic 2 E G O Er xx E x E 5 Pt NTC 1 8 2 LIN 1 2...
Страница 82: ...38 2 10 5 400 RAEE RAEE...
Страница 95: ...51 NOTE NOTES...
Страница 113: ...17 8 2 Falmec 70 C III...
Страница 114: ...18 1 99 1 9 1 99 0 250 C 10 1 2 1 99...
Страница 115: ...19 50 60 C RAEE RAEE 1 RAEE 25 2 400 2 RAEE...
Страница 122: ...26 NOTE NOTES...
Страница 123: ...27 NOTE NOTES...
Страница 124: ...28 NOTE NOTES...
Страница 125: ...29 NOTE NOTES...