59
FAULT
POSSIBLE CAUSES
REMEDY
USER
*ENG
Fridge frosting over
(cont)
Insufficient defrost
time.
Switch off unit and allow
to defrost.
✓
Restricted air flow
(Overloading fridge)
Remove products from
fridge to allow free air
flow.
✓
Hot-Plate not working
If only one side
working, high
probability of defective
heat pad element
Call engineer
✓
If both sides are not
working, high
probability that a fuse
has blown.
Call engineer
✓
Ovens slow to heat
Wrong temperature
setting
Change to desired
temperature setting
✓
Fridge not starting
Fridge requires to be
below 30°C before the
compressor will be
allowed to start.
Allow fridge cavity to cool
down.
✓
Fridge not reaching
temperature
Wrong settings in the
managers settings for
the Refrigeration Temp
Check and input correct
desired temperature.
✓
Chamber overloaded
–
not allowing air flow to
recirculate.
Remove some contents
to provide better airflow.
✓
Water on floor
Drip tray full.
Empty drip tray and wipe
tray and chamber dry.
✓
Yellow Flashing Light
Door(s) Left Open
Close Door
✓
Red Flashing Light
Door(s) Left open for
prolonged period.
Close Door
✓
‘Service due’ message
appears on screen.
Service limit reached.
Engineer to service unit.
On completion the
‘Service’ hours field (see
section 3.17) should be
reset to zero.
Note-Service limits
should be set in line with
the ‘Maintenance check’
statement on Pg 52.
✓