39
Australia
Technical Data
This cooker is designed for use on Natural Gas:-
A conversion for LP (LPG X Propane (2.75kPa)) gas is available.
.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION : Cooker back, serial number repeater badge below oven door opening.
Country of Destination: Australia
Gas
Electric
Natural Gas
1kPa
220 - 240V 50Hz
Propane
2.54kPa
(See appliance data badge for test pressures)
Dimensions
Overall height
minimum 893mm
maximum 920mm
Overall width
900mm See ‘Positioning of Cooker’
Overall depth
648mm
Space for fixing
See ‘Positioning of Cooker’
Minimum space above hotplate
650mm
Connections
Gas:
Electric
Rp 1/2 at rear right-hand side
220 - 240V 50Hz
Ratings
Natural Gas 1.0kPa
L.P. Gas 2.54kPa
Hotplate
Injector
Bypass
Injector
Bypass
Wok burner
15.2MJh
-1
internal 112
90
15.0MJh
-1
internal 66
54
external 164
external 91
Large Burner
12.3MJh
-1
165
80
12.0MJh
-1
89
41
Medium Burners
6.2MJh
-1
115
56
6.2MJh
-1
67
33
Small Burner
3.7MJh
-1
92
48
3.3MJh
-1
45
25
Gas burner inputs based on Gross Calorifi c Value
Main Oven
Tall Oven
Ovens
Forced air convection Forced air convection
Oven
Oven
2.7W
2.7kW
Grill
2.5kW
Maximum total electrical load at 240V
8kW (approximate total including oven lights, oven fan etc.)