Falcon G2962 Скачать руководство пользователя страница 6

SECTION 3 - SERVICING and 
CONVERSION 

Important 

BEFORE A TTEMP TING ANY SERVICING, SWITCH 
APPLIANCE OFF A T MAIN GAS AND 
ELECTRICITY SUPPLY IS OLA TORS. CA RE MUS T 
BE TAKEN  TO ENS URE THESE ARE NOT 
INA DVERTE NTLY SWITCHED ON DURING  TASK.  

Cert ain operations require pan to be tilted or the 

activator  repositioned with cont rol panel removed. If 
this is done electrically, care should be taken not to 
touch any live terminals and that control panel is 
supported adequately so that none  of the live switch   
parts or thermostat terminal can touch earthed parts. 

General Note 

AFTE R ANY MAINTE NANCE  TASK, CHECK 
APPLIANCE  TO ENS URE IT PERFORMS 
CORRE CTLY. CA RRY OUT ANY  NECESSARY 
ADJUS TME NTS AS DETA ILE D IN  THE  
APPROPRIA TE SECTION OF  THIS  DOCUME NT.  

After carrying out any servicing or exchange of gas   
components - 

ALWAYS CHECK FOR GAS TIGHTNESS 

Warning: Great care should be taken w hen checking 
for gas tightness, as, by necessity, electrical 
components will be  exposed and energised.  

3.1 CONV ERSION 

When changing from one gas family to another  
always ensure the following -   

Change main, pilot and cross-lighting  burner 
injectors. Refer to Section 1.8. Injectors must be re- 
sealed using thread sealant.  

Set pressures, refer to Section 3.8.  

Check pilot flame length. Refer to Section  1.10.  

Change data  plate.  

For detailed  proc edure, refer to appropriate section in   
this document.  

3.2 REMOV AL OF FRONT CONTROL P ANELS  

3.2.1 Main Control Panel 

Ensure pan is in DOW N position.  

Pull off thermostat control knob.  

On G2962 and G2994 models, remove handwheel by    
undoing central  fixing, take care to retain shaft key. 

Open drop down door.  

Remove fixings at corners of control panel bottom 
edge and also those in top  flange. 

Pull panel clear of appliance and carefully res t it on 
floor.  Take care not to strain wiring. 

Replace in reverse order.  

3.2.2 Lower Inner Control Panel 

Remove main control panel  before removing  fixings   
for lower panel and  pull clear. 

3.3 BURNERS  

Removal Of Main Burners 

Tilt pan to fully raised position to allow access to  
burner compartment.  

Remove fixings that retain burners to base of   
compartment.  

Slide burner from injector and remove.   

Replace in reverse order.  
 

3.4 INJECTORS  

3.4.1 Removal Of Main Burner Injectors 

Remove main burners as detailed in Section 3.3.  

Undo injectors or injector jets as required.  

Replace in reverse order, ensuring that correct  
injector is fitted to each  burner 

– refer to Section 1.8.  

Injectors must be re-sealed using thread sealant. 

 

3.4.2 Removal Of Cross Lighting  Burner  

Remove main control panel. (S ee Section 3.2)  

Tilt pan to fully raised position. On G2962/G2994 
models, temporarily re-fit handle (with key) upon 
shaft. On G2965/G2995, drop-down door must be  
closed to operate  foot bellows. 

Undo compression  fitting nut at cross-lighting burner   
venturi.  

From top, remove  fixings that secure cross-lighting 
burner and remove burner by lifting it up. 

Replace in reverse order.  

3.4.3 Removal Of Cross Lighting Injector  

The complete burner can be removed  as detailed in 
Section 3.4.2. Alternatively, injector can be removed 
leaving burner in position.  To ac hieve this, remove 
control panel, undo  gas supply pipe compression   
fitting nut and remove  fitting from burner  venturi tube.  

Injector can now be removed  for renewal or cleaning.  

When re-assembling, the injector must be re-sealed 
using thread sealant.  
 
 
 
 

Содержание G2962

Страница 1: ...D On completion of the installation these instructions should be left with the Engineer in Charge for reference during servicing Further to this The Users Instructions should be handed over to the Use...

Страница 2: ...ater and electrical supply external to appliance Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer...

Страница 3: ...ILATION This appliance must be installed in a suitably ventilated room in accordance with the regulations in force Sufficient ventilation natural or mechanical must be provided to supply adequate fres...

Страница 4: ...ssure Model NATURAL PROPANE G2962 2965 15 mbar 6 in w g 35 5 mbar 14 2 in w g G2994 2995 35 mbar 14 in w g Operating pressure is measured at outlet test point located on front face of multi functional...

Страница 5: ...red BLACK LIVE to terminal marked L or coloured RED Appliance must be protected by 3 amp fuse if 13 amp BS1363 plug is used Any other type of connection must be protected by 5 amp fuse at distribution...

Страница 6: ...e to retain shaft key Open drop down door Remove fixings at corners of control panel bottom edge and also those in top flange Pull panel clear of appliance and carefully rest it on floor Take care not...

Страница 7: ...onnection to pilot burner to remove electrode Undo connection lead to electrode Replace in reverse order ensuring connection to pilot assembly is not overtight as to crack electrode 3 6 2 Piezo Unit B...

Страница 8: ...Tightness Figure 1 3 8 2 To Check Adjust appliance operating gas pressure Natural Gas Appliances Only a Refer to Figure 1 Remove screw from outlet test point and connect manometer Remove protective ca...

Страница 9: ...not hold replace thermocouple If this does not correct condition replace multifunctional gas control unit 3 10 3 Checkout Multifunctional Control for complete function Put lighting sequence into oper...

Страница 10: ...switch b Undo fixing securing switch bracket to lower bearing block c Remove switch and bracket assembly Disconnect wires and note respective positions for correct replacement d Undo fixings which se...

Страница 11: ...riginal fixings unless direct replacements are available Replace in reverse order paying attention to note d above 3 17 DOOR SWITCH G2965 G2995 models only To Remove a Remove both control panels b Dis...

Страница 12: ...attached to the controls cover behind the controls compartment door Short Spares List Multifunctional Gas Control Burner Injector s Burner Injector Jet s Cross Lighter Jet s Pilot Jet s Thermocouple...

Страница 13: ...G2962 and G2994 BRATT PANS WIRING DIAGRAM...

Страница 14: ...G2965 and G2995 BRATT PANS WIRING DIAGRAM...

Отзывы: