Falcon G2962 Скачать руководство пользователя страница 5

SECTION 2 - ASSEMBLY and 
COMMISSIONING  

2.1 ASS EMBLY 

Position appliance and level  by adjusting leg levelling 
feet or castors as appropriat e. Each foot (on 

appliances with  feet ) contains a hole to enable floor   
fixing to be made. 

2.1.1 Appliance s on Ca stors 

Refer to addendum  T100286 supplied.

 

In addition, drain contents of pan before attempting to 
move appliance, pan must also be lowered down  fully 
prior to moving.  

2.2 CONNECTION TO THE GAS SUPPLY

 

Inlet connection terminates at bottom RH corner 
when  viewed  from rear and is Rp1/ 2 (1/2" BSP  
Female). Test for gas tightness. 

2.3 CONNECTION TO  ELECTRI CITY S UPPLY 

Make electrical connection.  

Appliance is designed for connection to a 230V AC 
supply. A 2 metre long mains lead is fitted as 
standard. Mains lead wires are coloured in 
accordance with the following code:  

Green and Yellow 

 

Earth   

Blue                                

Neutral  

Brown                             

Live 

 

The wires should be connected to plug  as follows: 

EARTH to terminal marked E, or coloured GREEN.  

NEUTRAL to terminal marked  N or coloured BLA CK. 

LIVE to terminal marked L, or coloured  RED.  

Appliance must be protected by 3 amp fus e if 13  amp 

(BS1363) plug is used. Any other type of connection 
must be prot ected by 5 amp  fuse at distribution 
board.  

Warning 

THIS APPLIANCE MUST BE  EARTHED.  

2.4 CONNECTION TO THE WATER SUPPLY 

Not applicable to this appliance. 

 

 

 

 

 

 

 

2.5 PRE-COMMISSIONING  CHECK 

Important 

After installation, the engineer should check that all 
gas connections are tight and do not leak. Also check 
that all electrical connections are secure.  

The installation engineer should check that the 
appliance is operating satisfactorily before leaving   
site. 

Particular attention should be given to pressure 
settings detailed in S ection 1.9 and pilot adjus tment 
as detailed in Section 1.10.  

2.6 INSTRUCTION TO US ER 

After installing and commissioning appliance, please 
hand User Instructions to user or purchaser and 

ensure that person(s) responsible understand the 
instructions and  proc edures for lighting, cleaning and   
correct use of appliance. 

It is important to ens ure that locations of gas isolating 

cock and electrical socket or switch are made known 
to user and procedures for  operating these in an 
emergency are demonstrated.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание G2962

Страница 1: ...D On completion of the installation these instructions should be left with the Engineer in Charge for reference during servicing Further to this The Users Instructions should be handed over to the Use...

Страница 2: ...ater and electrical supply external to appliance Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer...

Страница 3: ...ILATION This appliance must be installed in a suitably ventilated room in accordance with the regulations in force Sufficient ventilation natural or mechanical must be provided to supply adequate fres...

Страница 4: ...ssure Model NATURAL PROPANE G2962 2965 15 mbar 6 in w g 35 5 mbar 14 2 in w g G2994 2995 35 mbar 14 in w g Operating pressure is measured at outlet test point located on front face of multi functional...

Страница 5: ...red BLACK LIVE to terminal marked L or coloured RED Appliance must be protected by 3 amp fuse if 13 amp BS1363 plug is used Any other type of connection must be protected by 5 amp fuse at distribution...

Страница 6: ...e to retain shaft key Open drop down door Remove fixings at corners of control panel bottom edge and also those in top flange Pull panel clear of appliance and carefully rest it on floor Take care not...

Страница 7: ...onnection to pilot burner to remove electrode Undo connection lead to electrode Replace in reverse order ensuring connection to pilot assembly is not overtight as to crack electrode 3 6 2 Piezo Unit B...

Страница 8: ...Tightness Figure 1 3 8 2 To Check Adjust appliance operating gas pressure Natural Gas Appliances Only a Refer to Figure 1 Remove screw from outlet test point and connect manometer Remove protective ca...

Страница 9: ...not hold replace thermocouple If this does not correct condition replace multifunctional gas control unit 3 10 3 Checkout Multifunctional Control for complete function Put lighting sequence into oper...

Страница 10: ...switch b Undo fixing securing switch bracket to lower bearing block c Remove switch and bracket assembly Disconnect wires and note respective positions for correct replacement d Undo fixings which se...

Страница 11: ...riginal fixings unless direct replacements are available Replace in reverse order paying attention to note d above 3 17 DOOR SWITCH G2965 G2995 models only To Remove a Remove both control panels b Dis...

Страница 12: ...attached to the controls cover behind the controls compartment door Short Spares List Multifunctional Gas Control Burner Injector s Burner Injector Jet s Cross Lighter Jet s Pilot Jet s Thermocouple...

Страница 13: ...G2962 and G2994 BRATT PANS WIRING DIAGRAM...

Страница 14: ...G2965 and G2995 BRATT PANS WIRING DIAGRAM...

Отзывы: