SECTION 2 - ASSEMBLY and
COMMISSIONING
2.1 ASS EMBLY
Position appliance and level by adjusting leg levelling
feet or castors as appropriat e. Each foot (on
appliances with feet ) contains a hole to enable floor
fixing to be made.
2.1.1 Appliance s on Ca stors
Refer to addendum T100286 supplied.
In addition, drain contents of pan before attempting to
move appliance, pan must also be lowered down fully
prior to moving.
2.2 CONNECTION TO THE GAS SUPPLY
Inlet connection terminates at bottom RH corner
when viewed from rear and is Rp1/ 2 (1/2" BSP
Female). Test for gas tightness.
2.3 CONNECTION TO ELECTRI CITY S UPPLY
Make electrical connection.
Appliance is designed for connection to a 230V AC
supply. A 2 metre long mains lead is fitted as
standard. Mains lead wires are coloured in
accordance with the following code:
Green and Yellow
Earth
Blue
Neutral
Brown
Live
The wires should be connected to plug as follows:
EARTH to terminal marked E, or coloured GREEN.
NEUTRAL to terminal marked N or coloured BLA CK.
LIVE to terminal marked L, or coloured RED.
Appliance must be protected by 3 amp fus e if 13 amp
(BS1363) plug is used. Any other type of connection
must be prot ected by 5 amp fuse at distribution
board.
Warning
THIS APPLIANCE MUST BE EARTHED.
2.4 CONNECTION TO THE WATER SUPPLY
Not applicable to this appliance.
2.5 PRE-COMMISSIONING CHECK
Important
After installation, the engineer should check that all
gas connections are tight and do not leak. Also check
that all electrical connections are secure.
The installation engineer should check that the
appliance is operating satisfactorily before leaving
site.
Particular attention should be given to pressure
settings detailed in S ection 1.9 and pilot adjus tment
as detailed in Section 1.10.
2.6 INSTRUCTION TO US ER
After installing and commissioning appliance, please
hand User Instructions to user or purchaser and
ensure that person(s) responsible understand the
instructions and proc edures for lighting, cleaning and
correct use of appliance.
It is important to ens ure that locations of gas isolating
cock and electrical socket or switch are made known
to user and procedures for operating these in an
emergency are demonstrated.