Falcon G2962 Скачать руководство пользователя страница 2

 

Warranty Policy Shortlist 

Warranty does not cover :- 

Correcting faults caused by incorrect installation of a product. 

Where an engineer cannot gain access to a site or a product.  

Repeat commission  visits. 

Replacement of  any parts where damage has been caused by misuse.  

Engineer  waiting time will be chargeable.  

Routine maintenance and cleaning.  

Gas conversions i.e. Natural to Propane gas. 

Descaling of  water products and cleaning of water sensors where softeners/conditioners are not fitted, or are fitted 
and not maintained.  

Blocked drains. 

Independent steam generation systems. 

Gas, water  and  electrical supply external to appliance.  

Light bulbs. 

Re-installing  vacuum in kettle jackets. 

Replacement of  grill burner ceramics when damage has been clearly caused by misuse.  

Where an engineer  finds no fault with a product that has been  reported faulty. 

Re-s etting or adjustment of thermostats when appliance is operating to specification. 

Cleaning and unblocking of fryer  filter systems due to customer misuse.  

Lubrication and adjustment of door catches.  

Cleaning and Maintenance  
 

•      Cleaning of burner jets 

 

•      Poor combustion caused by lack of cleaning            
•      Lubrication of moving parts 
•      Lubrication of gas cocks 

 

 

•      Cleaning/adjustment of pilots 

 

•      Correction of gas pressure to appliance. 

 

•      Renewing of electric cable ends. 

 

•      Replacement of fuses  

 

•      Corrosion caused by use of chemical cleaners. 

 
 

 

 

 

Содержание G2962

Страница 1: ...D On completion of the installation these instructions should be left with the Engineer in Charge for reference during servicing Further to this The Users Instructions should be handed over to the Use...

Страница 2: ...ater and electrical supply external to appliance Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer...

Страница 3: ...ILATION This appliance must be installed in a suitably ventilated room in accordance with the regulations in force Sufficient ventilation natural or mechanical must be provided to supply adequate fres...

Страница 4: ...ssure Model NATURAL PROPANE G2962 2965 15 mbar 6 in w g 35 5 mbar 14 2 in w g G2994 2995 35 mbar 14 in w g Operating pressure is measured at outlet test point located on front face of multi functional...

Страница 5: ...red BLACK LIVE to terminal marked L or coloured RED Appliance must be protected by 3 amp fuse if 13 amp BS1363 plug is used Any other type of connection must be protected by 5 amp fuse at distribution...

Страница 6: ...e to retain shaft key Open drop down door Remove fixings at corners of control panel bottom edge and also those in top flange Pull panel clear of appliance and carefully rest it on floor Take care not...

Страница 7: ...onnection to pilot burner to remove electrode Undo connection lead to electrode Replace in reverse order ensuring connection to pilot assembly is not overtight as to crack electrode 3 6 2 Piezo Unit B...

Страница 8: ...Tightness Figure 1 3 8 2 To Check Adjust appliance operating gas pressure Natural Gas Appliances Only a Refer to Figure 1 Remove screw from outlet test point and connect manometer Remove protective ca...

Страница 9: ...not hold replace thermocouple If this does not correct condition replace multifunctional gas control unit 3 10 3 Checkout Multifunctional Control for complete function Put lighting sequence into oper...

Страница 10: ...switch b Undo fixing securing switch bracket to lower bearing block c Remove switch and bracket assembly Disconnect wires and note respective positions for correct replacement d Undo fixings which se...

Страница 11: ...riginal fixings unless direct replacements are available Replace in reverse order paying attention to note d above 3 17 DOOR SWITCH G2965 G2995 models only To Remove a Remove both control panels b Dis...

Страница 12: ...attached to the controls cover behind the controls compartment door Short Spares List Multifunctional Gas Control Burner Injector s Burner Injector Jet s Cross Lighter Jet s Pilot Jet s Thermocouple...

Страница 13: ...G2962 and G2994 BRATT PANS WIRING DIAGRAM...

Страница 14: ...G2965 and G2995 BRATT PANS WIRING DIAGRAM...

Отзывы: