SECTION 1 

– INSTALLATION 

UNLESS OTHE RWISE S TA TED, PARTS WHICH HAVE BEEN PROTECTE D BY THE MANUFA CTURE R ARE 
NOT  TO BE ADJUS TE D BY THE INS TALLER.  

1.1 MODEL  NUMBERS, NETT WEIGHTS and 
DIMENSIONS 

MODEL

 

WIDTH 

mm 

DEPTH 

mm 

HEIGHT 

mm 

WEIGHT 

kg

 

WEIGHT 

lbs

 

G2962 

600 

770 

870 

120 

265 

G2965 

600 

770 

870 

120 

265 

G2994 

900 

770 

870 

165 

364 

G2995 

900 

770 

870 

165 

364 

 

1.2 SITING 

The appliance should be installed on a level, fireproof 

surface, in a well lit and draught free position within a 
suitably  ventilat ed room. If floor is constructed of 
combustible mat erial then local  fire  requirements 
should be checked to ensure compliance. A clear 
space of  150mm should be left bet ween appliance 
rear and any combustible wall. A minimum  vertical 
clearance of 900mm above top edge of  appliance is  
required.  

Important 

If  appliance is to be installed in a suite formation with 

matching appliances then instructions for all models 
should be consulted in order to determine  necessary 
clearances to any combustible  rear wall or overlying 
surface(s). Some appliances require greater 
clearances than others.  The largest figure quoted in 
the individual instructions will therefore determine   
clearance of the complete suite adjoining applianc es. 

Flue discharges  vertically along top  rear of appliance.   

THERE MUS T BE NO DIRECT  CONNE CTION OF 
THE FLUE TO  THE OUTS IDE AIR OR  TO A  
MECHA NICAL E XTRACTION SYS TEM.  

See Section 1.3  for  ventilation details. 

After appliance position has been established, it is 
recommended that the feet (on  an appliance fitted   
with feet) be secured to floor using holes provided.  

 

1.3 VENTILATI ON 

This appliance must be installed in a suitably 
ventilated room in accordance with the regulations in  
force. 

Sufficient  ventilation, natural or mechanical, must be 
provided to supply adequat e fresh air for proper 
combustion.   

 

It should  also prevent occurrenc e of unaccept able 
concentrations of substances harmful to health in the 

location where equipment is installed. It is also 
required to be able to remove any such products that 
may occur, safely and efficiently. 

Recommendations for V entilation  of  Catering 
Appliances are provided in BS5440: 2. For multiple 
installations, requirements for individual appliances 
should be added together. Installation should be 

made in  accordance wit h local and/or national  
regulations which apply at the time. 

A qualified installer MUS T  be employed.  

1.4 GAS SUPPLY 

The incoming service must be of sufficient size to 

supply full rate without excessive pressure drop.  The 
gas meter should be checked, preferably by the gas 
supplier to ensure meter is adequat e to deal  with rate 
of gas supply required  for the appliance in addition to   
any other gas equipment installed.  

Installation pipes should  be fitted in accordance  with 

IGE/UP/2.  The size of pipework  from meter to 
appliance must not be less than appliance inlet 
connection Rp1/2

 (1/2" BSP female). An isolating 

cock that is easily accessible to user must be located 
close to appliance to allow shut down during any 
emergency or routine servicing.  The installation must 
be tested for gas tightness. Details are given in   
IGE/UP/1.  

Position of isolating cock should be shown to  
responsible person(s).  

The gas supply tubing or hose must comply with 
national requirements in force and require to be   
periodically examined and replaced as nec essary. 

Flexible hose length must not exceed 1.5M. 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание G2962

Страница 1: ...D On completion of the installation these instructions should be left with the Engineer in Charge for reference during servicing Further to this The Users Instructions should be handed over to the Use...

Страница 2: ...ater and electrical supply external to appliance Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer...

Страница 3: ...ILATION This appliance must be installed in a suitably ventilated room in accordance with the regulations in force Sufficient ventilation natural or mechanical must be provided to supply adequate fres...

Страница 4: ...ssure Model NATURAL PROPANE G2962 2965 15 mbar 6 in w g 35 5 mbar 14 2 in w g G2994 2995 35 mbar 14 in w g Operating pressure is measured at outlet test point located on front face of multi functional...

Страница 5: ...red BLACK LIVE to terminal marked L or coloured RED Appliance must be protected by 3 amp fuse if 13 amp BS1363 plug is used Any other type of connection must be protected by 5 amp fuse at distribution...

Страница 6: ...e to retain shaft key Open drop down door Remove fixings at corners of control panel bottom edge and also those in top flange Pull panel clear of appliance and carefully rest it on floor Take care not...

Страница 7: ...onnection to pilot burner to remove electrode Undo connection lead to electrode Replace in reverse order ensuring connection to pilot assembly is not overtight as to crack electrode 3 6 2 Piezo Unit B...

Страница 8: ...Tightness Figure 1 3 8 2 To Check Adjust appliance operating gas pressure Natural Gas Appliances Only a Refer to Figure 1 Remove screw from outlet test point and connect manometer Remove protective ca...

Страница 9: ...not hold replace thermocouple If this does not correct condition replace multifunctional gas control unit 3 10 3 Checkout Multifunctional Control for complete function Put lighting sequence into oper...

Страница 10: ...switch b Undo fixing securing switch bracket to lower bearing block c Remove switch and bracket assembly Disconnect wires and note respective positions for correct replacement d Undo fixings which se...

Страница 11: ...riginal fixings unless direct replacements are available Replace in reverse order paying attention to note d above 3 17 DOOR SWITCH G2965 G2995 models only To Remove a Remove both control panels b Dis...

Страница 12: ...attached to the controls cover behind the controls compartment door Short Spares List Multifunctional Gas Control Burner Injector s Burner Injector Jet s Cross Lighter Jet s Pilot Jet s Thermocouple...

Страница 13: ...G2962 and G2994 BRATT PANS WIRING DIAGRAM...

Страница 14: ...G2965 and G2995 BRATT PANS WIRING DIAGRAM...

Отзывы: