Falcon G2962 Скачать руководство пользователя страница 4

1.5 ELECTRICAL SUPPLY 

These appliances are designed  for operation on a   
230V~ 50Hz 3A electrical supply. 

As mains lead wire colours may not correspond  with 
the markings which identify plug terminals, proceed 
as follows: 

The wire coloured GREEN and YELLOW must be 
connected to plug terminal which is marked with the 
letter E or the earth symbol or coloured GREE N or 

GREEN  and YELLOW. 

The wire coloured BLUE must be connected to 
terminal marked with letter  N or coloured BLA CK. 

The wire coloured BROWN must be connected to 
terminal marked with letter  L or coloured RE D.  

 
 

1.6 WATER SUPPLY 

Not applicable to these applianc es. 

 
 

1.7 TOTAL RATED  HEAT INP UTS 

– 

NATURAL  (I

2

H) and PROP ANE (I

3

P) GAS  

Model  

kW (nett) 

Btu/hr (gross) 

G2962/2965 

9.8 

36,800 

G2994/2995 

15.9 

59,700 

 

1.8 INJECTOR SIZES - 

NATURAL  (I

2

H) and PROP ANE (I

3

P) GAS  

 

 

 

 

1.9 GAS PRESS URE 

The appliance operates at the following pressures - 

Supply Pressure (All Models) 

NA TURAL 

PROPANE  

20 mbar 

8 in. w.g. 

37 mbar 

14.8 in. w.g.  

 

Operating Pressure  

Model 

NA TURAL 

PROPANE  

G2962/2965 

15 mbar 

6 in. w.g. 

35.5 mbar 

14.2 in. w.g.  

G2994/2995 

35 mbar 

14 in. w.g.  

 

Operating pressure is measured at outlet test point 
located on front face of multi-functional control 

– (See 

Figure 1, Servicing Section  3.8) 

 

1.10 BURNER ADJUSTMENT  

The only adjustment necessary on main burner is the 
correct setting of gas pressures as described in  
Section 1.9.  

No aeration adjustment is provided.  

Pilot flame should envelop approximately 6mm to 
10mm of thermocouple tip. Pilot flame can be 
adjusted  using the Pilot Adjustment screw on  front of 

Multi-functional Control Valve  (turn screw clockwise 
to reduce and anti-clockwise to increase) 

– (see  

Figure 1, Servicing Section  3.8).  

If  any adjustment is required, appliance must be 

serviced.  

 

 

 

 

 

 

 

 

 

 

G2962/2965 

NA TURAL 

PROPANE  

MAIN BURNER 
RH 

Amal 470 

Amal 180 

MAIN BURNER 
LH 

Amal 400 

Amal 180 

PILOT 
BURNER 

SIT No. 36 

SIT No. 19 

CROSS-LIGHTING 
BURNER 

Amal 75 

Amal 20 

MAIN BURNER 
RH 

Amal 490 

Amal 190 

MAIN BURNER 
CENTRE 

Amal 400 

Amal 190 

MAIN BURNER 
LH 

Amal 430 

Amal 190 

PILOT 
BURNER 

SIT No. 36 

SIT No. 19 

CROSS-LIGHTING 
BURNER - LH 

Amal 75 

Amal 20 

CROSS-LIGHTING 
BURNER - RH 

Amal 85 

Amal 20 

G2994/2995 

NA TURAL 

PROPANE  

Содержание G2962

Страница 1: ...D On completion of the installation these instructions should be left with the Engineer in Charge for reference during servicing Further to this The Users Instructions should be handed over to the Use...

Страница 2: ...ater and electrical supply external to appliance Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer...

Страница 3: ...ILATION This appliance must be installed in a suitably ventilated room in accordance with the regulations in force Sufficient ventilation natural or mechanical must be provided to supply adequate fres...

Страница 4: ...ssure Model NATURAL PROPANE G2962 2965 15 mbar 6 in w g 35 5 mbar 14 2 in w g G2994 2995 35 mbar 14 in w g Operating pressure is measured at outlet test point located on front face of multi functional...

Страница 5: ...red BLACK LIVE to terminal marked L or coloured RED Appliance must be protected by 3 amp fuse if 13 amp BS1363 plug is used Any other type of connection must be protected by 5 amp fuse at distribution...

Страница 6: ...e to retain shaft key Open drop down door Remove fixings at corners of control panel bottom edge and also those in top flange Pull panel clear of appliance and carefully rest it on floor Take care not...

Страница 7: ...onnection to pilot burner to remove electrode Undo connection lead to electrode Replace in reverse order ensuring connection to pilot assembly is not overtight as to crack electrode 3 6 2 Piezo Unit B...

Страница 8: ...Tightness Figure 1 3 8 2 To Check Adjust appliance operating gas pressure Natural Gas Appliances Only a Refer to Figure 1 Remove screw from outlet test point and connect manometer Remove protective ca...

Страница 9: ...not hold replace thermocouple If this does not correct condition replace multifunctional gas control unit 3 10 3 Checkout Multifunctional Control for complete function Put lighting sequence into oper...

Страница 10: ...switch b Undo fixing securing switch bracket to lower bearing block c Remove switch and bracket assembly Disconnect wires and note respective positions for correct replacement d Undo fixings which se...

Страница 11: ...riginal fixings unless direct replacements are available Replace in reverse order paying attention to note d above 3 17 DOOR SWITCH G2965 G2995 models only To Remove a Remove both control panels b Dis...

Страница 12: ...attached to the controls cover behind the controls compartment door Short Spares List Multifunctional Gas Control Burner Injector s Burner Injector Jet s Cross Lighter Jet s Pilot Jet s Thermocouple...

Страница 13: ...G2962 and G2994 BRATT PANS WIRING DIAGRAM...

Страница 14: ...G2965 and G2995 BRATT PANS WIRING DIAGRAM...

Отзывы: