1.5 ELECTRICAL SUPPLY
These appliances are designed for operation on a
230V~ 50Hz 3A electrical supply.
As mains lead wire colours may not correspond with
the markings which identify plug terminals, proceed
as follows:
The wire coloured GREEN and YELLOW must be
connected to plug terminal which is marked with the
letter E or the earth symbol or coloured GREE N or
GREEN and YELLOW.
The wire coloured BLUE must be connected to
terminal marked with letter N or coloured BLA CK.
The wire coloured BROWN must be connected to
terminal marked with letter L or coloured RE D.
1.6 WATER SUPPLY
Not applicable to these applianc es.
1.7 TOTAL RATED HEAT INP UTS
–
NATURAL (I
2
H) and PROP ANE (I
3
P) GAS
Model
kW (nett)
Btu/hr (gross)
G2962/2965
9.8
36,800
G2994/2995
15.9
59,700
1.8 INJECTOR SIZES -
NATURAL (I
2
H) and PROP ANE (I
3
P) GAS
1.9 GAS PRESS URE
The appliance operates at the following pressures -
Supply Pressure (All Models)
NA TURAL
PROPANE
20 mbar
8 in. w.g.
37 mbar
14.8 in. w.g.
Operating Pressure
Model
NA TURAL
PROPANE
G2962/2965
15 mbar
6 in. w.g.
35.5 mbar
14.2 in. w.g.
G2994/2995
35 mbar
14 in. w.g.
Operating pressure is measured at outlet test point
located on front face of multi-functional control
– (See
Figure 1, Servicing Section 3.8)
1.10 BURNER ADJUSTMENT
The only adjustment necessary on main burner is the
correct setting of gas pressures as described in
Section 1.9.
No aeration adjustment is provided.
Pilot flame should envelop approximately 6mm to
10mm of thermocouple tip. Pilot flame can be
adjusted using the Pilot Adjustment screw on front of
Multi-functional Control Valve (turn screw clockwise
to reduce and anti-clockwise to increase)
– (see
Figure 1, Servicing Section 3.8).
If any adjustment is required, appliance must be
serviced.
G2962/2965
NA TURAL
PROPANE
MAIN BURNER
RH
Amal 470
Amal 180
MAIN BURNER
LH
Amal 400
Amal 180
PILOT
BURNER
SIT No. 36
SIT No. 19
CROSS-LIGHTING
BURNER
Amal 75
Amal 20
MAIN BURNER
RH
Amal 490
Amal 190
MAIN BURNER
CENTRE
Amal 400
Amal 190
MAIN BURNER
LH
Amal 430
Amal 190
PILOT
BURNER
SIT No. 36
SIT No. 19
CROSS-LIGHTING
BURNER - LH
Amal 75
Amal 20
CROSS-LIGHTING
BURNER - RH
Amal 85
Amal 20
G2994/2995
NA TURAL
PROPANE