6.2.2 Fryer maximum basket loading (All models)
Pre-blanched chilled fries– 2 x 1.5kg baskets.
Frozen fries – 2 x 1.2kg baskets.
6.2.3 Using the Controller
E401/401F Models Only - Manually Operated
When unit has been switched on as detailed in Section
6.2.1 above, fryer may be operated as follows.
Oil temperature will be governed by controller to desired
set temperature, selected by user on control knob.
E402/402F Models only –
Programmable
When unit is lit as detailed in Section 6.2.1 lighting
instructions above, fryer may be operated as follows:-
NOTES:
1) The oil temperature will be governed by controller at a
factory
preset temperature of 180
⁰
C. See
Section 6.3.1 for instructions on how to change set
temperature.
2) When actual temperature is within 10
⁰
C of set point
the display reads redy. See Section 7.3 for
instructions on how to display actual or set
temperature).
3) Before carrying out any cooking operations, controller
should be set up for particular application of use
(e.g. up to four timer programmes, product frying
temperature,
⁰
C/
⁰
F). This can all be carried out using
the following guide in Section 6.3.2.
Operating the Controller:
a) Start a timing cycle: Press any product key (1 to 4)
to start a timing cycle. If key is programmed, correct
time will be displayed and will immediately start to
count down and LED above key will flash. DONE
will display when cook cycle has ended and
alarm
will
sound.
If
DONE
is
displayed
immediately and alarm sounds, key has not been
programmed See Section 6.3.2 for programming
details.
b) Stop a timing cycle: Press and hold an active
product key for 3 seconds, or press key 3
times within 2 seconds.
c) Respond to a DONE alarm: Cancel signal by
pressing same product key used to start timing
cycle.
Operating the Controller (cont’d):
d) Multiple timing cycles: If a second or third product
key is pressed while first is still active, shortest time
remaining key is displayed and only the LED above
key
flashes, other(s) remain constantly lit.
Once shortest time programme ends and is
accepted, next shortest is displayed and LED above
flashes. Note: All product key timers will count down
although not displayed until shorter one ends.
e) Action Alarms (Shake, etc.): If control is programmed
for action alarm, they will signal at a preset time
during the timing cycle. The signal, a dual-rhythm
beeping, will last 5 seconds and then self cancel.
The display will flash action alarm time and will
continue counting towards 0:00.
f) Viewing Actual/Set Temperatures: Pressing the
temperature key once will display “AXXX” where XXX
is actual temperature (°C or °F depending on controller
programming – See Section 6.3.1). Pressing
temperature key again within 5 seconds displays
“PXXX” where XXX is programmed set temperature
controller (°C or °F depending on how controller is
programmed – See Section 6.3.1). If temperature key
is not pressed again within 5 seconds, display returns
to idle or timer mode.
9
Содержание E401
Страница 13: ...E401F WIRING DIAGRAM...
Страница 14: ...E401 WIRING DIAGRAM...
Страница 15: ...E402F WIRING DIAGRAM...
Страница 16: ...E402 WIRING DIAGRAM...
Страница 17: ...E401F CIRCUIT DIAGRAM...
Страница 18: ...E401 CIRCUIT DIAGRAM...
Страница 19: ...E402F CIRCUIT DIAGRAM...
Страница 20: ...E402 CIRCUIT DIAGRAM...