background image

 

 

 
 
 

 

 

 

 
                                    

 

Solid top low flame 
adjustment screw

 

 

 Solid top burner test point

 

3.5.2 Injectors

 

Injectors are best cleaned with a wooden splinter or soft 

fuse wire. Metal reamers may distort or increase orifice 

size and their use should be avoided.

 

 

3.6  THERMOCOUPLES and  

FLAME FAILURE DEVICE (FFD)

 

3.6.1  Open Top Flame Failure Device Magnet Unit  

To remove and replace FFD magnet unit, the following 
procedures must be followed. Isolate Gas supply.

 

Remove hob components as detailed in Section 3.2.2. 

Undo FFD thermocouple at rear of tap, undo FFD  section 

at tap rear and withdraw.

 

Replace in reverse order.

 

 

3.6.2  Open Top Thermocouple

 

Remove hob as detailed in Section 3.2.2.

 

Remove  nut  that  secures  thermocouple  to  burner 

support  bracket  and  pull  thermocouple through support 

bracket from underside.

 

Undo thermocouple connection at FFD section of gas tap 

and carefully remove thermocouple.

 

Replace  in  reverse  order,  taking  care  to  position  tip 

correctly  in  relation  to    burner    ports.    Thermocouple 

tip  should  be  35mm  above  support  bracket.  Ensure 

thermocouple  does  not  touch  any  part  of  burner  when 
fully re-assembled. (Fig 11) 

 

                                                        

 

 

 

3.6.3  Oven Flame Failure Device Magnet Unit

 

The oven FFD magnet unit is an integral thermostat part. 

Remove  hob  components  as  detailed  in  Section  3.2.2 
to gain access to FFD. Isolate Gas supply.

 

Undo FFD thermocouple at thermostat rear. Undo rear 

FFD section and withdraw. Replace in reverse order.

 

                            

Figure 12 

 

3.6.4  Oven Thermocouple

 

To  Remove Thermocouple

 

Remove facia panel as detailed in Section 3.2.1. 

Remove  hob  fitments.  See  Sections  3.2.2  or  3.2.3 

as required.

 

Remove RH side panel.

 

Undo  thermocouple  nut  at  thermostat  rear. 

 

Open over doors. remove shelves and base plate.  

Undo n u t    that   secures   thermocouple   to   burner 

bracket.   Remove  sensor from burner bracket. 

Release thermocouple from clips in oven chamber. 

Remove Thermocouple by feeding through slot in oven 

side panel. Replace  in  reverse  order,  taking  care  not 

to  over tighten, ensure side wall insulation around 

thermocouple access  slot is undamaged

 

then ensuring 

position as indicated  in Figure 12.

 

 

3.7 OVEN  IGNITERS and ELECTRODES

 

Igniter  is  piezo  spark  type  and  contains  no  batteries. 

Unit  comprises  piezo spark igniter, lead  and  electrode 

assembly.  Lead  and  earth  lead  are  push-fit  at  igniter 

end.  Oven  igniter  electrode,  Thermocouple,  and  burner 

ports should  be aligned as indicated in Figure 12. 

3.7.1  Oven Igniter

 

Remove facia panel as detailed in Section 3.2.1. 

Disconnect igniter earth wire and .

 

P u l l   b a c k  insulated sleeve and remove igniter lead 

connection from spark igniter.

 

Undo nut that secures igniter in position.  Remove 

Igniter. Replace in reverse order,  

 

3.7.2  Oven Electrode

 

Remove oven shelves and base plate. 

R e m o v e   t i e   w r a p s   a n d   p u l l   b a c k  

i n s u l a t e d   s l e e v e .  

Disconnect igniter lead from electrode.

 

Undo fixing that secures electrode to burner bracket. 

Remove electrode and replace in reverse order ensuring 

position is as indicated in Figure 12.

 

Note: Care should be taken not to damage electrode 

Important: if spark is present but burner will not light, 

ensure gas is present and dimensions are as (Fig 12)

 

Figure 11 

Содержание Dominator Plus G3151

Страница 1: ...ions should be left with the Engineer in Charge for reference during servicing Further to this The Users Instructions should be handed over to the User having had a demonstration of the operation and...

Страница 2: ...on systems Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where...

Страница 3: ...VENTILATION Adequate ventilation must be provided to supply sufficient fresh air for combustion and allow easy removal of combustion products which may be harmful to health Recommendations for Ventil...

Страница 4: ...rnor BSP is provided on Natural gas units This should be adjusted to achieve an operating pressure at control manifold of 15mbar For muti burner systems approximately half of the burners should be on...

Страница 5: ...ner heads fit loosely upon aluminium bases of lift off construction 2 1 1 Fryplate Accessory If fryplate Figure 2 is supplied refer to user instructions for details Important note this should be opera...

Страница 6: ...d select 210 C setting Allow oven to heat up and check temperature is 210 C 10 C If reading is outwith specified range the thermostat may be faulty In this case unit should be serviced see thermostat...

Страница 7: ...gure 7 a Remove control panel b Unscrew and remove existing low position screw from open top tap c Insert replacement screw into open top tap and secure Repeat for all taps d Refit control panel 3 1 3...

Страница 8: ...venturi that sit loosely upon injector holder The hob is retained by ballstud fixings at each corner Lift hob clear to access burner support brackets 3 2 3 To Remove Hob Remove fixings that secure fr...

Страница 9: ...ove Thermocouple Remove facia panel as detailed in Section 3 2 1 Remove hob fitments See Sections 3 2 2 or 3 2 3 as required Remove RH side panel Undo thermocouple nut at thermostat rear Open over doo...

Страница 10: ...otects the breather hole When checking for gas leaks around governor be aware that unburned gas may be vented occasionally to release pressure on diaphragm This should not be confused with a gas leak...

Отзывы: