3.8 OVEN THERMOSTAT

 

Remove  control  knobs  and  fascia  panel  as  

detailed  in  Section 3.2.1.

 

Remove hob fitments as detailed in Sections 3.2.2 and

 

3.2.3 as appropriate.

 

Undo thermocouple connection at thermostat rear. 

Disconnect oven burner pipe.

 

From inside oven, release clips that secures thermostat 

capillary  to  oven  side  wall.  Undo  fixings  that  secure 

thermostat to manifold.

 

Remove  thermostat  by  carefully  feeding  capillary  and 

phial through crown plate.

 

Replace  all  parts  in  reverse  order.  Renew  manifold 

gasket if necessary.

 

3.8.1  Thermostat Calibration

 

The thermostat should not be calibrated. If temperature is 

outwith  specified  tolerances,  replace  thermostat  and 

return faulty thermostat to Falcon Quality Department.

 

 

3.9 OPEN TOP and SOLID TOP GAS TAPS 

Note

 

Plugs  and  bodies  are  machined  in  pairs  and  are 

therefore not interchangeable. Always clean one tap 

at a time.

 

3.9.1 Service  - Isolate from gas supply.

 

Remove  control  knobs  and  fascia  panel  as  detailed 

in  Section 3.2.1.

 

Remove fixings from front of tap body. Withdraw spindle 

and  niting  arrangement  to  allow  plug  to  be  eased  out. 

Clean gas tap plug with a soft rag and regrease using an 

approved  high  temperature  lubricant.  Take  care  not  to 

over-grease as surplus may cause gasway blockage.

 

Replace parts in correct order and check gas tightness.

 

3.9.2  Removal – isolate from gas supply.

 

Remove  control  knobs  and  fascia  panel  as  detailed 

in  Section 3.2.1.

 

Remove hob fitments as detailed in Sections 3.2.2 and

 

3.2.3 as appropriate.

 

Disconnect thermocouple connection at gas tap rear. 

 

 

 

3.10   GOVERNOR (Natural Gas Models Only)

 

The  governor  supplied  is  maintenance  free.  Check 

that  blue  dust  cap  is  covering  vent  and  in  good 

condition as  this protects the breather hole.

 

When  checking  for  gas  leaks  around  governor,  be 

aware  that  unburned  gas  may  be  vented  occasionally 

to  release  pressure  on  diaphragm. This  should  not  be 

confused with  a gas leak.

 

 

3.11  FAULT CHECK LIST

 

If a flame is not established on any burners (hob or 

oven),  follow this check list.

 

1. Check mains gas is ON.

 

2. Check pressure at test point to ensure gas is flowing to 

unit.

 

3. If pressure does not register then check governor is 

fully operational or check for line blockage.

 

4. If gas is present, check burner injector for blockage.

 

5. If  injector  is  OK  then  check  FFD  is  engaging  and 

passing gas.

 

6. OVEN ONLY - Check for spark at spark electrode.

 

7. OVEN ONLY - If there is no spark then check spark 

d i m e n s i o n s ( f i g 1 2 )  and HT lead connections. 

Also check igniter.

 

8. OVEN ONLY – Note: Spark may be present but will still 

not light burner unless dimensions relative to burner 

are as Fig 12.

 

Note: If after adjusting the electrode to the correct 

dimensions (fig 12), a spark is not present, or is 

present but will not light burner, check the following: 

Check Spark lead and return earth wire connections at 

piezo spark igniter body. 

Check for clean contact between burner fixing feet and 

oven base, using spring washers under screw heads. 

9. If flame is still not present, then re-check from start.

 

 
 

If  flame  is  established  but  not  maintained,  follow 

this  check list.

 

1. Check thermocouple is positioned correctly in burner 

flame. (fig 12)  Burner ports must be clean.

 

2. Check thermocouple is not damaged and is secured 

to gas valve FFD section to allow FFD to energise.

 

3. Check FFD is energising and maintaining flame.

 

4. If,  after  carrying  out  the  above,  burner  is  still  not 

maintaining flame then re-check from start.

 

 

 
 
 
SECTION 4 - SPARES and

 

ACCESSORIES

 

When ordering spare parts, always quote appliance type 

and serial number.

 

This information will be found on data badge attached to 

base plate. 

 

 

Содержание Dominator Plus G3151

Страница 1: ...ions should be left with the Engineer in Charge for reference during servicing Further to this The Users Instructions should be handed over to the User having had a demonstration of the operation and...

Страница 2: ...on systems Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where...

Страница 3: ...VENTILATION Adequate ventilation must be provided to supply sufficient fresh air for combustion and allow easy removal of combustion products which may be harmful to health Recommendations for Ventil...

Страница 4: ...rnor BSP is provided on Natural gas units This should be adjusted to achieve an operating pressure at control manifold of 15mbar For muti burner systems approximately half of the burners should be on...

Страница 5: ...ner heads fit loosely upon aluminium bases of lift off construction 2 1 1 Fryplate Accessory If fryplate Figure 2 is supplied refer to user instructions for details Important note this should be opera...

Страница 6: ...d select 210 C setting Allow oven to heat up and check temperature is 210 C 10 C If reading is outwith specified range the thermostat may be faulty In this case unit should be serviced see thermostat...

Страница 7: ...gure 7 a Remove control panel b Unscrew and remove existing low position screw from open top tap c Insert replacement screw into open top tap and secure Repeat for all taps d Refit control panel 3 1 3...

Страница 8: ...venturi that sit loosely upon injector holder The hob is retained by ballstud fixings at each corner Lift hob clear to access burner support brackets 3 2 3 To Remove Hob Remove fixings that secure fr...

Страница 9: ...ove Thermocouple Remove facia panel as detailed in Section 3 2 1 Remove hob fitments See Sections 3 2 2 or 3 2 3 as required Remove RH side panel Undo thermocouple nut at thermostat rear Open over doo...

Страница 10: ...otects the breather hole When checking for gas leaks around governor be aware that unburned gas may be vented occasionally to release pressure on diaphragm This should not be confused with a gas leak...

Отзывы: