background image

IMPORTANT INFORMATION

 

 

Warranty Policy Shortlist

 

 

Warranty does not cover :-

 

•  Correcting faults caused by incorrect installation of a product.

 

•  Where an engineer cannot gain access to a site or a product.

 

•  Repeat commission visits.

 

•  Replacement of any parts where damage has been caused by misuse.

 

•  Engineer waiting time will be chargeable.

 

•  Routine maintenance and cleaning.

 

•  Gas conversions i.e. Natural to Propane gas.

 

•  Descaling of water products and cleaning of water sensors where softeners/ conditioners are not fitted, 

or are fitted and not maintained.

 

•  Blocked drains

 

•  Independent steam generation systems.

 

•  Gas, water and electrical supply external to unit.

 

•  Light bulbs

 

•  Re-installing vacuum in kettle jackets.

 

•  Replacement of grill burner ceramics when damage has been clearly caused by misuse.

 

•  Where an engineer finds no fault with a product that has been reported faulty.

 

•  Re-setting or adjustment of thermostats when unit is operating to specification.

 

•  Cleaning and unblocking of fryer filter systems due to customer misuse.

 

•  Lubrication and adjustment of door catches.

 

•  Cleaning and Maintenance

 

• Cleaning of burner jets

 

• Poor combustion caused by lack of cleaning

 

• Lubrication of moving parts

 

• Lubrication of gas cocks

 

• Cleaning/adjustment of pilots

 

• Correction of gas pressure to appliance.

 

• Renewing of electric cable ends.

 

• Replacement of fuses

 

• Corrosion caused by use of chemical cleaners.

 

Содержание Dominator Plus G3151

Страница 1: ...ions should be left with the Engineer in Charge for reference during servicing Further to this The Users Instructions should be handed over to the User having had a demonstration of the operation and...

Страница 2: ...on systems Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where...

Страница 3: ...VENTILATION Adequate ventilation must be provided to supply sufficient fresh air for combustion and allow easy removal of combustion products which may be harmful to health Recommendations for Ventil...

Страница 4: ...rnor BSP is provided on Natural gas units This should be adjusted to achieve an operating pressure at control manifold of 15mbar For muti burner systems approximately half of the burners should be on...

Страница 5: ...ner heads fit loosely upon aluminium bases of lift off construction 2 1 1 Fryplate Accessory If fryplate Figure 2 is supplied refer to user instructions for details Important note this should be opera...

Страница 6: ...d select 210 C setting Allow oven to heat up and check temperature is 210 C 10 C If reading is outwith specified range the thermostat may be faulty In this case unit should be serviced see thermostat...

Страница 7: ...gure 7 a Remove control panel b Unscrew and remove existing low position screw from open top tap c Insert replacement screw into open top tap and secure Repeat for all taps d Refit control panel 3 1 3...

Страница 8: ...venturi that sit loosely upon injector holder The hob is retained by ballstud fixings at each corner Lift hob clear to access burner support brackets 3 2 3 To Remove Hob Remove fixings that secure fr...

Страница 9: ...ove Thermocouple Remove facia panel as detailed in Section 3 2 1 Remove hob fitments See Sections 3 2 2 or 3 2 3 as required Remove RH side panel Undo thermocouple nut at thermostat rear Open over doo...

Страница 10: ...otects the breather hole When checking for gas leaks around governor be aware that unburned gas may be vented occasionally to release pressure on diaphragm This should not be confused with a gas leak...