MCSi-60/84
Digital Brushless AC servo drive system - Ref.0707
Function:
Variable internally useful to the system. It measures the
internal load level of the calculation of the i
2
t at the motor in
percentage used over the maximum.
Valid values:
0, ..., 100 %.
Default value:
0 %.
Function:
Shows the load percentage on the ballast resistor in a drive.
Useful for the i
2
t protection of the resistor. A value greater
than 100 % in this variable causes error E314.
Valid values:
0, ..., 100 %.
Default value:
0 %.
Function:
Selector that determines whether the ballast resistor is
external or internal.
Valid values:
0/1 external / internal (by default).
M group. Motor
Function:
Motor identification. The limits of certain parameters depend
on the value of MP1 (e.g. The upper limit of SP10 is 110 %
of the motor rated speed) like its default parameter
initialization through GC10.
See command GC10.
KV36
USER, RO
I
2
tMotor
KV40
USER, RO
IntBallastOverload
KV41
USER, RW
BallastSelect
MP1
BASIC, RW
MotorType
CONNECTION
c
SIZE/POWER
MAXIMUM
SPEED
TYPE
FEEDBACK
BRAKE/SEAL
OPTION
MOTOR TYPE: FSA, FSP
A: LONG MOTORS
P: SHORT MOTORS
SHAFT
& FLANGE
WINDING
VOLTAGE 220 V