Page 11 of 128
Errors 1000-1999
1019
'No measurement has been taken on the requested axis (axes)'
DETECTION
During execution.
CAUSE
Function G101is being used to include the measurement offset on an axis for which:
• No previous measurement has been taken (G100).
• The measurement taken (G100) has been canceled (G102).
SOLUTION
Take a measurement with the axis on which to apply function G101.
1020
'Negative ramp time'
DETECTION
During execution.
CAUSE
Using function G132, a negative ramp time has been programmed.
SOLUTION
The ramp time must be equal to or greater than zero.
1021
'Ramp time out of range'
DETECTION
During execution.
CAUSE
With function G132, a ramp time value too high has been programmed.
SOLUTION
Check the program.
1022
'Percentage of Feed-Forward out of range'
DETECTION
During execution.
CAUSE
The probable causes are:
• With function G134, too high a value has been programmed for the percentage
of Feed-Forward.
• With function G135, too high a value has been programmed for the percentage
of AC-Forward.
SOLUTION
The percentage of Feed-Forward or AC-Forward must be greater than zero and
smaller than 120.
1023
'Wrong set number
DETECTION
During execution.
CAUSE
The programmed set number for the axis is wrong.
SOLUTION
The set programmed for the axis must be greater than zero and smaller than or equal
to machine parameter NPARSETS of the axis.
1024
'Set number out of range'
DETECTION
During execution.
CAUSE
The programmed parameter set value for the axis is too high.
SOLUTION
The maximum value allowed for the set number is 65535.
1025
'Programmed distance equal to zero'
DETECTION
During execution.
CAUSE
No movement has been programmed in the G63 block.
SOLUTION
Program a movement.
1026
'Wrong circular path with the programmed radius'
DETECTION
During execution.
CAUSE
The programmed radius for the circular interpolation is too small.
SOLUTION
Check the program.
1027
'The starting point and the end point of the circular path are the same (infinite
solutions)'
DETECTION
During execution.
CAUSE
A zero radius has been programmed for the circular interpolation and there are infinite
solutions.
SOLUTION
Check the program.
Содержание CNC8 070
Страница 1: ...CNC8070 R EF 0402 ERROR SOLUTIONS...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 84: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 78 of 128 Errors 1000 1999...
Страница 110: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 104 of 128 Errors 6000 6999...
Страница 116: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 110 of 128 Errors 7000 7999...
Страница 130: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 124 of 128 Tool and tool magazine table...